Rietveld quantitative amorphous content analysis

被引:309
作者
De La Torre, AG [1 ]
Bruque, S [1 ]
Aranda, MAG [1 ]
机构
[1] Univ Malaga, Dept Quim Inorgan Cristalog & Mineral, E-29071 Malaga, Spain
来源
JOURNAL OF APPLIED CRYSTALLOGRAPHY | 2001年 / 34卷
关键词
D O I
10.1107/S0021889801002485
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A procedure for Rietveld quantitative amorphous content analysis (RQACA) is outlined, in which the effects of systematic errors in the powder patterns are studied. The method derives the amorphous content from the small overestimation of an internal crystalline standard in a Rietveld refinement of an appropriate mixture. Of several standards studied, Al2O3 gave the best results. The statistical analysis of standard mixtures with a known amount of amorphous content indicated that this is a precise and accurate tool. It enables the measurement of the amorphous content with an accuracy close to 1%. Sample preparation and Rietveld analysis need to be optimized in order to minimize the systematic errors. The analysis of samples with phases displaying strong preferred orientation effects gives very high errors in the amorphous content. Samples with different absorption coefficients have also been studied in order to evaluate the importance of microabsorption. This plays an important role but it can be adequately corrected if the absorption coefficients of the standard and the sample are not very different. RQACA has been applied to tricalcium silicate, C3S, which is the main component of Portland cement. The average amorphous content of C3S, after microabsorption correction using two standards of higher and lower absorption coefficients, was found to be 19%.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 29 条
[1]   X-ray diffraction analysis of powders for determination of alite structure [J].
Bellotto, M ;
Signes-Frehel, M .
JOURNAL DE PHYSIQUE IV, 1998, 8 (P5) :511-518
[2]   QUANTITATIVE PHASE-ANALYSIS USING THE RIETVELD METHOD [J].
BISH, DL ;
HOWARD, SA .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1988, 21 (02) :86-91
[3]  
Brindley G. W., 1945, PHILOS MAG, V36, P347, DOI DOI 10.1080/14786444508520918
[4]  
CLINE JP, 1998, DENV XRAY C ABSTR BO
[5]   Full phase analysis of portland clinker by penetrating synchrotron powder diffraction [J].
de la Torre, AG ;
Cabeza, A ;
Calvente, A ;
Bruque, S ;
Aranda, MAG .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :151-156
[6]   CORRECTION OF INTENSITIES FOR PREFERRED ORIENTATION IN POWDER DIFFRACTOMETRY - APPLICATION OF THE MARCH MODEL [J].
DOLLASE, WA .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1986, 19 (pt 4) :267-272
[7]   A CORRECTION FOR POWDER DIFFRACTION PEAK ASYMMETRY DUE TO AXIAL DIVERGENCE [J].
FINGER, LW ;
COX, DE ;
JEPHCOAT, AP .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1994, 27 :892-900
[8]   CRYSTAL-STRUCTURES OF THE LOW-TEMPERATURE QUARTZ-TYPE PHASES OF SIO2 AND GEO2 AT ELEVATED PRESSURE [J].
GLINNEMANN, J ;
KING, HE ;
SCHULZ, H ;
HAHN, T ;
LAPLACA, SJ ;
DACOL, F .
ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1992, 198 (3-4) :177-212
[9]   X-ray powder diffraction quantitative analysis performed in situ at high temperature:: application to the determination of NiO in ceramic pigments [J].
Gualtieri, AF ;
Mazzucato, E ;
Venturelli, P ;
Viani, A ;
Zannini, P ;
Petras, L .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1999, 32 :808-813
[10]   Quantitative Rietveld analysis of aluminous cement clinker phases [J].
Guirado, F ;
Galí, S ;
Chinchón, S .
CEMENT AND CONCRETE RESEARCH, 2000, 30 (07) :1023-1029