The transfer point is a novel measure of embryo placement

被引:39
作者
Frankfurter, D [1 ]
Silva, CP [1 ]
Mota, F [1 ]
Trimarchi, JB [1 ]
Keefe, DL [1 ]
机构
[1] Women & Infants Hosp Rhode Isl, Brown Med Sch, Div Biol & Med, Providence, RI 02905 USA
关键词
IVF-ET; ultrasonography-guided embryo transfer; uterine fundus; transfer point;
D O I
10.1016/S0015-0282(03)00263-2
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To study the relationship between IVF-ET pregnancy outcomes and measures of embryo placement. Design: Case-control study. Setting: Tertiary care center. Patient(s): Twenty-three patients who underwent two ultrasonography-guided ETs, of which one resulted in a clinical pregnancy and the other did not. Main Outcome Measure(s): Point of embryo placement normalized to the endometrial cavity length (the transfer point), distance from the point of embryo placement to the uterine fundus, time required for ET, contact with the uterine fundus, and evidence of trauma. Videotaped ETs were quantitatively analyzed. Result(s): From February 1, 2000, to March 31, 2001, videotaped ETs from 23 pairs of pregnant and nonpregnant cycles were identified. Embryo placement was more shallow in pregnancy cycles than in nonpregnancy cycles. The groups did not differ in the absolute distance of embryo placement to the fundus, ovarian stimulation, or other features of the ET. Conclusion: The transfer point may serve as a better marker of embryo position than does the absolute distance to the uterine fundus.
引用
收藏
页码:1416 / 1421
页数:6
相关论文
共 20 条
[1]   TRANSFER OF EMBRYOS INTO THE UTERUS - HOW MUCH DO TECHNICAL FACTORS AFFECT PREGNANCY RATES [J].
ALSHAWAF, T ;
DAVE, R ;
HARPER, J ;
LINEHAN, D ;
RILEY, P ;
CRAFT, I .
JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 1993, 10 (01) :31-36
[2]   The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF:: a controlled, ultrasound-guided study [J].
Coroleu, B ;
Barri, PN ;
Carreras, O ;
Martínez, F ;
Parriego, M ;
Hereter, L ;
Parera, N ;
Veiga, A ;
Balasch, J .
HUMAN REPRODUCTION, 2002, 17 (02) :341-346
[3]   Uterine contractions at the time of embryo transfer alter pregnancy rates after in-vitro fertilization [J].
Fanchin, R ;
Righini, C ;
Olivennes, F ;
Taylor, S ;
de Ziegler, D ;
Frydman, R .
HUMAN REPRODUCTION, 1998, 13 (07) :1968-1974
[4]  
FEO D, 1963, ENDOCRINOLOGY, V72, P305
[5]   Blastocyst transfer after enzymatic treatment of the zona pellucida: improving in-vitro fertilization and understanding implantation [J].
Fong, CY ;
Bongso, A ;
Ng, SC ;
Kumar, J ;
Trounson, A ;
Ratnam, S .
HUMAN REPRODUCTION, 1998, 13 (10) :2926-2932
[6]   FACTORS AFFECTING INTRAUTERINE CONTRACEPTIVE DEVICE PERFORMANCE .1. ENDOMETRIAL CAVITY LENGTH [J].
HASSON, HM ;
BERGER, GS ;
EDELMAN, DA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1976, 126 (08) :973-981
[7]   Pregnancy rates after embryo transfer depend on the provider at embryo transfer [J].
Hearns-Stokes, RM ;
Miller, BT ;
Scott, L ;
Creuss, D ;
Chakraborty, PK ;
Segars, JH .
FERTILITY AND STERILITY, 2000, 74 (01) :80-86
[8]   Impact of the "physician factor" on pregnancy rates in a large assisted reproductive technology program: do too many cooks spoil the broth? [J].
Karande, VC ;
Morris, R ;
Chapman, C ;
Rinehart, J ;
Gleicher, N .
FERTILITY AND STERILITY, 1999, 71 (06) :1001-1009
[9]  
KERIN JFP, 1981, LANCET, V2, P726
[10]   What factors are important for successful embryo transfer after in-vitro fertilization? [J].
Kovacs, GT .
HUMAN REPRODUCTION, 1999, 14 (03) :590-592