Glomerular structure in the normal human kidney: Differences between living and cadaver donors

被引:12
作者
Caramori, ML [1 ]
Basgen, JM [1 ]
Mauer, M [1 ]
机构
[1] Univ Minnesota, Dept Pediat, Minneapolis, MN 55455 USA
来源
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2003年 / 14卷 / 07期
关键词
D O I
10.1097/01.ASN.0000075554.31464.DA
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Glomerular structure has been studied in tissues derived from normal living and cadaver kidney donors. Values obtained in such subjects were considered interchangeable and have been used to define the normal parameters when evaluating the effects of various renal diseases. The present study evaluated glomerular structure by light and electron microscopy in 83 living and 53 cadaver kidney donors. Glomerular basement membrane (GBM) width (356 +/- 52 versus 329 +/- 45 nm), glomerular volume (1.64 +/- 0.47 versus 1.33 +/- 0.39 X 10(6) mum(3)), and mesangial matrix volume per glomerulus (0.15 +/- 0.05 versus 0.12 +/- 0.04 X 10(6) mum(3)) were significantly greater in cadaver compared with living kidney donors, respectively. It is hypothesized that glomerular and extracellular matrix swelling is associated with the cadaver kidney preservation process. This study suggests that the normal values for glomerular structure should be derived only from living kidney donor tissues.
引用
收藏
页码:1901 / 1903
页数:3
相关论文
共 8 条
[1]   Cellular basis of diabetic nephropathy 1. Study design and renal structural-functional relationships in patients with long-standing type 1 diabetes [J].
Caramori, ML ;
Kim, Y ;
Huang, CM ;
Fish, AJ ;
Rich, SS ;
Miller, ME ;
Russell, G ;
Mauer, M .
DIABETES, 2002, 51 (02) :506-513
[2]   GLOMERULAR STRUCTURE IN NONPROTEINURIC IDDM PATIENTS WITH VARIOUS LEVELS OF ALBUMINURIA [J].
FIORETTO, P ;
STEFFES, MW ;
MAUER, M .
DIABETES, 1994, 43 (11) :1358-1364
[3]   THE EFFICIENCY OF SYSTEMATIC-SAMPLING IN STEREOLOGY AND ITS PREDICTION [J].
GUNDERSEN, HJG ;
JENSEN, EB .
JOURNAL OF MICROSCOPY-OXFORD, 1987, 147 :229-263
[4]   DETERMINATION OF MEMBRANE THICKNESS DISTRIBUTION FROM ORTHOGONAL INTERCEPTS [J].
JENSEN, EB ;
GUNDERSEN, HJG ;
OSTERBY, R .
JOURNAL OF MICROSCOPY, 1979, 115 (JAN) :19-33
[5]   Measurement of glomerular volume in needle biopsy specimens [J].
MacLeod, JM ;
White, KE ;
Tate, H ;
Bilous, RW .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (02) :239-243
[6]  
Nyengaard JR, 1999, J AM SOC NEPHROL, V10, P1100
[7]   CELL AND MATRIX COMPONENTS OF THE GLOMERULAR MESANGIUM IN TYPE-I DIABETES [J].
STEFFES, MW ;
BILOUS, RW ;
SUTHERLAND, DER ;
MAUER, SM .
DIABETES, 1992, 41 (06) :679-684
[8]  
STEFFES MW, 1983, LAB INVEST, V49, P82