Mobile phone platform as portable chemical analyzer

被引:147
作者
Garcia, Antonio [2 ]
Erenas, M. M. [1 ]
Marinetto, Eugenio D. [2 ]
Abad, Carlos A. [2 ]
de Orbe-Paya, Ignacio [1 ]
Palma, Alberto J. [2 ]
Capitan-Vallvey, Luis F. [1 ]
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, ECsens, E-18071 Granada, Spain
[2] Univ Granada, Fac Sci, Dept Elect & Comp Technol, ECsens, E-18071 Granada, Spain
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 156卷 / 01期
关键词
Mobile phone; Portable instrumentation; Imaging; Disposable optical sensor; Potassium determination; POTASSIUM DETERMINATION; MICROFLUIDIC DEVICES; DATA-ACQUISITION; SCANNER; SENSOR; PAPER;
D O I
10.1016/j.snb.2011.04.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a mobile phone platform for portable chemical analysis is presented. This platform is based on the use of the built-in camera for capturing the image of a single-use colorimetric chemical sensor, while a custom-developed software application processes this image for obtaining its characteristic H (hue) value, which is related to analyte concentration. This software application is optimized for mobile phone usage, thus preserving battery life and targeting reduced computation time through a customized image processing scheme including a modified monodimensional edge detection algorithm. Meanwhile, the influence of physical and chemical factors has been characterized, with results showing that the presented platform provides accurate results even when variations on distance from phone to sensor, image focusing, or image centering are induced. In the same way, factors such as indicator concentration and membrane thickness have been shown to have negligible effects on the obtained H values. The calibration and testing procedures have shown that the presented platform is able to provide a detection limit of 3.1 x 10(-5) M in a range of 3.1 x 10(-5)-0.1 M with a relative standard deviation for inter-membrane reproducibility lower than 1.6% for potassium concentration determination in solution. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 359
页数:10
相关论文
共 38 条
[1]   A simple and cost-effective method, as an appropriate alternative for visible spectrophotometry: development of a dopamine biosensor [J].
Abbaspour, Abdolkarim ;
Khajehzadeh, Abdolreza ;
Ghaffarinejad, Ali .
ANALYST, 2009, 134 (08) :1692-1698
[2]  
*ANDR, 2010, DEV GUID
[3]  
[Anonymous], J SENSORS
[4]  
*APPL IOS DEV CTR, 2010, TECHN DOC
[5]  
ARM, 2010, CORT A8 TECHN REF MA CORTEX A8 TECHNICAL
[6]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[7]   Example of use of a desktop scanner for data acquisition in a colorimetric assay [J].
Birch, NC ;
Stickle, DF .
CLINICA CHIMICA ACTA, 2003, 333 (01) :95-96
[8]  
BREMNES D, 2009, Patent No. 2009054729
[9]  
Cadle BA, 2010, SUBST ABUS-RES TREAT, V4, P21
[10]   Use of the Hue Parameter of the Hue, Saturation, Value Color Space As a Quantitative Analytical Parameter for Bitonal Optical Sensors [J].
Cantrell, K. ;
Erenas, M. M. ;
de Orbe-Paya, I. ;
Capitan-Vallvey, L. F. .
ANALYTICAL CHEMISTRY, 2010, 82 (02) :531-542