A novel technique, using radioluminography, for the measurement of uniformity of radiolabelled antibody distribution in a colorectal cancer xenograft model

被引:27
作者
Flynn, AA [1 ]
Green, AJ [1 ]
Boxer, GM [1 ]
Casey, JL [1 ]
Pedley, RB [1 ]
Begent, RHJ [1 ]
机构
[1] Royal Free Hosp, Sch Med, Dept Clin Oncol, CRC Targeting & Imaging Grp, London NW3 2PF, England
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 01期
关键词
radioimmunotherapy; radioluminography; uniformity; skew; Kurtosis; Lilliefor's;
D O I
10.1016/S0360-3016(98)00275-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Radioimmunotherapy of cancer employs an antitumour antibody to carry a radionuclide selectively to deposits of cancer. Conventional dose estimates, based on the Medical Internal Radiation Dose (MIRD) formulation, assume uniform distribution of radiolabelled antitumour antibody within tissue source regions. This assumption has been tested by using a statistical model to predict the pixel value distribution obtained from the digitised radioluminographs of a known radioactive source. The model uses the statistical nature of the detection of radiation where any uniform source distribution can be expected to have a detected histogram of pixel counts that is normal or Gaussian. Therefore, any test for the degree of normality in the detected distribution is also a measure of the degree of uniformity in the source. Methods and Materials: Three statistical techniques have been used to test the normality of the histogram of pixel values produced from the antibody distribution in a tissue section. Kurtosis, skew, and Lilliefor's are tests for normality and have statistically defined critical values for a normal distribution. After administration of I-125-labelled F(ab)(2) antibody to nude mice bearing the LS174T colorectal cancer xenograft, the uniformity of antibody distribution in tumour and healthy tissues is measured using the radioluminographs of formalin-fixed paraffin sections. The test statistic for kurtosis, skew, and Lilliefor's is calculated for each tissue and is compared to critical values from statistical tables. Results: The radiolabelled antibody is distributed uniformly in liver, spleen, muscle, lung, and colon and, therefore, conforms to conventional use of the MIRD formulation. The study showed that the kidney cortex and medulla should be considered separately in macroscopic absorbed-dose calculations, as should bone marrow and hard bone. Antibody heterogeneity in the tumour necessitates the incorporation of a microdosimetric tumour model into a macrodosimetry model for the accurate calculation of absorbed dose in all tissues. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:183 / 189
页数:7
相关论文
共 28 条
[1]  
BERGER MJ, 1978, MIRD PAMPHLET, V7
[2]   LOCALIZATION OF MONOCLONAL-ANTIBODIES REACTING WITH DIFFERENT EPITOPES ON CARCINOEMBRYONIC ANTIGEN (CEA) - IMPLICATIONS FOR TARGETED THERAPY [J].
BOXER, GM ;
ABASSI, AM ;
PEDLEY, RB ;
BEGENT, RHJ .
BRITISH JOURNAL OF CANCER, 1994, 69 (02) :307-314
[3]  
CHUNG JK, 1994, J NUCL MED, V35, P1499
[4]  
Conover W. J., 1980, PRACTICAL NONPARAMET
[5]  
GREENWOOD FC, 1963, BIOCHEM J, V89, P116
[6]  
HITCHINS RN, 1989, NUKLEARMED, V28, P29
[7]   CARCINOEMBRYONIC ANTIGEN (CEA) EXPRESSION AND HETEROGENEITY IN PRIMARY AND AUTOLOGOUS METASTATIC GASTRIC TUMORS DEMONSTRATED BY A MONOCLONAL-ANTIBODY [J].
HOCKEY, MS ;
STOKES, HJ ;
THOMPSON, H ;
WOODHOUSE, CS ;
MACDONALD, F ;
FIELDING, JWL ;
FORD, CHJ .
BRITISH JOURNAL OF CANCER, 1984, 49 (02) :129-133
[8]  
HUI TE, 1994, CANCER, V73, P951
[9]  
HUMM JL, 1993, J NUCL MED, V34, P1811
[10]   THE SPATIAL ACCURACY OF CELLULAR DOSE ESTIMATES OBTAINED FROM 3D RECONSTRUCTED SERIAL TISSUE AUTORADIOGRAPHS [J].
HUMM, JL ;
MACKLIS, RM ;
LU, XQ ;
YANG, Y ;
BUMP, K ;
BERESFORD, B ;
CHIN, LM .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (01) :163-180