In vivo multiple-mouse MRI at 7 Tesla

被引:75
作者
Bock, NA
Nieman, BJ
Bishop, JB
Henkelman, RM
机构
[1] Hosp Sick Children, Mouse Imaging Ctr, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
parallel imaging; mouse imaging; phenotyping; mouse models of disease; high field;
D O I
10.1002/mrm.20683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost artifacts across images from the different RF coils. Grid phantoms were used to measure image distortion in different positions in the coils. The brains of 7 live mice were imaged in 3D in the RF coil array, and a second array of 16 RF coils was used to 313 image the whole bodies of 16 fixed, contrast agent-perfused mice. The images of the 7 live mouse brains at 156 mu m isotropic resolution and the 16 whole fixed mice at 100 mu m isotropic resolution were of high quality and free of artifacts. We have thus shown that multiple-mouse MRI increases throughput for live and fixed mouse experiments by a factor equaling the number of RF coils in the scanner.
引用
收藏
页码:1311 / 1316
页数:6
相关论文
共 19 条
[1]   Multiple-mouse MRI [J].
Bock, NA ;
Konyer, NB ;
Henkelman, RM .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :158-167
[2]   Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields [J].
Cassidy, PJ ;
Schneider, JE ;
Grieve, SM ;
Lygate, C ;
Neubauer, S ;
Clarke, K .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) :229-237
[3]   Multiple mouse biological loading and monitoring system for MRI [J].
Dazai, J ;
Bock, NA ;
Nieman, BJ ;
Davidson, LM ;
Henkelman, RM ;
Chen, XJ .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :709-715
[4]   In vivo measurements of T1 relaxation times in mouse brain associated with different modes of systemic administration of manganese chloride [J].
Kuo, YT ;
Herlihy, AH ;
So, PW ;
Bhakoo, KK ;
Bell, JD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :334-339
[5]   Hexagonal zero mode TEM coil: A single-channel coil design for imaging multiple small animals [J].
Lazovic, J ;
Stojkovic, DS ;
Collins, CM ;
Yang, QX ;
Vaughan, JT ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) :1150-1157
[6]   RETROSPECTIVE CARDIAC GATING - A REVIEW OF TECHNICAL ASPECTS AND FUTURE-DIRECTIONS [J].
LENZ, GW ;
HAACKE, EM ;
WHITE, RD .
MAGNETIC RESONANCE IMAGING, 1989, 7 (05) :445-455
[7]   Super-parallel MR microscope [J].
Matsuda, Y ;
Utsuzawa, S ;
Kurimoto, T ;
Haishi, T ;
Yamazaki, Y ;
Kose, K ;
Anno, I ;
Marutani, M .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :183-189
[8]   Micro-MRI at 11.7 T of a Murine Brain Tumor Model Using Delayed Contrast Enhancement [J].
Moats, Rex A. ;
Velan-Mullan, Sendhil ;
Jacobs, Russell ;
Gonzalez-Gomez, Ignacio ;
Dubowitz, David J. ;
Taga, Takashi ;
Khankaldyyan, Vazgen ;
Schultz, Linda ;
Fraser, Scott ;
Nelson, Marvin D. ;
Laug, Walter E. .
Molecular Imaging, 2003, 2 (03) :150-158
[9]  
MORRIS HD, 2001, P 9 ANN M ISMRM GLAS, P19
[10]  
NIEMAN BJ, 2004, P ISMRM 12 ANN M KYO, P338