Mass spectral interferences in the determination of trace levels of precious metals in human blood using quadrupole magnetic sector field and inductively coupled plasma mass spectrometry

被引:50
作者
Begerow, J
Dunemann, L
机构
[1] Medizinisches Inst. F. Umwelthygiene, Department of Analytical Chemistry, D-40225 Düsseldorf
关键词
magnetic sector field HR-ICP-MS; Pd; Au; blood; spectral interferences;
D O I
10.1039/ja9961100303
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The results of the determination of physiological levels of precious metals in blood with a new type of magnetic sector field high resolution (HR)-ICP-MS instrument are presented. Palladium levels, for example, ranged between 32 and 102.5 ng l(-1), HR-ICP-MS operating in the low resolution mode is advantageous for such ultratrace analyses as it is about 100 times more sensitive than in the HR mode or conventional quadrupole (Q)-ICP-MS. It is also shown that the determination of Rh and Pd in the ng l(-1) range is impaired by spectral interferences originating from Cd+, Pb2+, SrO+, RbO+ CuAr+ and ZnAr+. Using standard instrumental operating conditions on a Q-ICP-MS instrument, Pb2+:Pb+ and SrO+:Sr+ ratios were found to be about 0.1%, which results in a severe impairment of the determination of physiological Rh and Pd concentrations in body fluids. The resolution of the HR instrument used (m/Delta m = 7500) was not sufficient to separate Rh and Pd from all spectral overlaps. These remaining spectral interferences can only be overcome by an appropriate sample preparation step.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 16 条
  • [1] ALT F, 1988, MIKROCHIM ACTA, V111, P299
  • [2] INTERNAL LEAD AND CADMIUM EXPOSURE IN 6-YEAR-OLD CHILDREN FROM WESTERN AND EASTERN GERMANY
    BEGEROW, J
    FREIER, I
    TURFELD, M
    KRAMER, U
    DUNEMANN, L
    [J]. INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1994, 66 (04) : 243 - 248
  • [3] BEGEROW J, UNPUB
  • [4] BEGEROW J, 1995, THESIS CLAUSTHAL ZEL
  • [5] HIGH-RESOLUTION ICP-MS - A NEW CONCEPT FOR ELEMENTAL MASS-SPECTROMETRY
    GIESSMANN, U
    GREB, U
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (4-5): : 186 - 193
  • [6] OXIDE AND DOUBLY CHARGED ION RESPONSE OF A COMMERCIAL INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY INSTRUMENT
    GRAY, AL
    WILLIAMS, JG
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (01) : 81 - 82
  • [7] JARVIS KE, 1991, HDB INDUCTIVELY COUP, P25
  • [8] OPTIMIZATION IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    LONG, SE
    BROWN, RM
    [J]. ANALYST, 1986, 111 (08) : 901 - 906
  • [9] ADSORPTIVE VOLTAMMETRIC PROCEDURE FOR THE DETERMINATION OF PLATINUM BASE-LINE LEVELS IN HUMAN-BODY FLUIDS
    MESSERSCHMIDT, J
    ALT, F
    TOLG, G
    ANGERER, J
    SCHALLER, KH
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (04): : 391 - 394
  • [10] TRACE-ELEMENT REFERENCE VALUES IN TISSUES FROM INHABITANTS OF THE EUROPEAN COMMUNITY .1. A STUDY OF 46 ELEMENTS IN URINE, BLOOD AND SERUM OF ITALIAN SUBJECTS
    MINOIA, C
    SABBIONI, E
    APOSTOLI, P
    PIETRA, R
    POZZOLI, L
    GALLORINI, M
    NICOLAOU, G
    ALESSIO, L
    CAPODAGLIO, E
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1990, 95 : 89 - 105