A combined linear ion trap time-of-flight system with improved performance and MSn capabilities

被引:73
作者
Collings, BA [1 ]
Campbell, JM [1 ]
Mao, DM [1 ]
Douglas, DJ [1 ]
机构
[1] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
关键词
D O I
10.1002/rcm.440
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A detailed description of a linear ion trap time-of-flight (TOF) mass spectrometer system, capable of sequential mass spectrometry (MS'), is given. Many improvements have been incorporated since the initial description of this system (Rapid Commun. Mass Spectrom. 1998; 12:1463-1474). The pressure in the trap has been lowered from 7.0 to 1.8 mTorr, resulting in an increase in the mass resolution of ion excitation from 75 to 240. Use of the system for MS3 is demonstrated. Dipole excitation of the n = I harmonic, instead of the n = 0 fundamental frequency of ion motion, is shown to have a higher frequency resolution, f/Deltaf, but lower mass resolution, m/Deltam. Both experiments and modeling demonstrate that at the lower pressure there is less collisional cooling of ions in the axial and radial directions of the trap. The efficiency of trapping is shown to be nearly 100% for periods up to 5 s. The demonstrated mass range for mass analysis has been extended to greater than m/z 16 250. To avoid the formation of adduct ions when trapping protein ions for extended times requires ultra-high vacuum cleanliness conditions, even though the trap operates in the mTorr-pressure range. Upgrading the TOF to a reflectron with higher quality ion optics results in an increase in the mass resolution of the TOF mass spectrometer to about 5000 at m/z 750. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1777 / 1795
页数:19
相关论文
共 32 条
  • [1] ASHCROFT NW, 1988, SOLID STATE PHYS, P385
  • [2] ATKINS PW, 1978, PHYSICAL CHEM, P802
  • [3] ION CONFINEMENT IN THE COLLISION CELL OF A MULTIQUADRUPOLE MASS-SPECTROMETER - ACCESS TO CHEMICAL-EQUILIBRIUM AND DETERMINATION OF KINETIC AND THERMODYNAMIC PARAMETERS OF AN ION-MOLECULE REACTION
    BEAUGRAND, C
    JAOUEN, D
    MESTDAGH, H
    ROLANDO, C
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (13) : 1447 - 1453
  • [4] A new technique for unbiased external ion accumulation in a quadrupole two-dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Belov, ME
    Nikolaev, EN
    Alving, K
    Smith, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) : 1172 - 1180
  • [5] Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Udseth, HR
    Conrads, TP
    Veenstra, TD
    Masselon, CD
    Gorshkov, MV
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 253 - 261
  • [6] Campbell JM, 1998, RAPID COMMUN MASS SP, V12, P1463, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1463::AID-RCM357>3.3.CO
  • [7] 2-8
  • [8] An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system
    Cha, BC
    Blades, M
    Douglas, DJ
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5647 - 5654
  • [9] Chen YL, 1998, RAPID COMMUN MASS SP, V12, P1003, DOI 10.1002/(SICI)1097-0231(19980815)12:15<1003::AID-RCM275>3.0.CO
  • [10] 2-#