Comparison of histometric data obtained by optical coherence tomography and routine histology -: art. no. 044008

被引:28
作者
Gambichler, T [1 ]
Boms, S [1 ]
Stücker, M [1 ]
Kreuter, A [1 ]
Sand, M [1 ]
Moussa, G [1 ]
Altmeyer, P [1 ]
Hoffmann, K [1 ]
机构
[1] Ruhr Univ Bochum, Dept Dermatol, D-44791 Bochum, Germany
关键词
epidermal thickness; interferometry; bioengineering; noninvasive skin imaging; histopathology;
D O I
10.1117/1.2039086
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There is a lack of systematic investigations comparing optical coherence tomography (OCT) with histology. OCT assessments were performed on the upper back of 16 healthy subjects. Epidermis thickness (ET) was assessed using three methods: first, peak-to-valley analysis of the A-scan (ET-OCT-V); second, manual measurements in the OCT images (ET-OCT-M); third, light microscopic determination using routine histology (ET-Histo). The relationship between the different methods was assessed by means of the Pearson correlation procedure and Bland and Altman plots. We observed a strong correlation between ET-Histo (79.4 +/- 21.9 mu m) and ET-OCT-V (79.2 +/- 15.5 mu m, r=0.77) and ET-OCT-M (82.9 +/- 15.8 mu m, r=0.75), respectively. Bland and Altman plots revealed a bias of -0.19 mu m (95% limits of agreement: -27.94 mu m to 27.56 mu m) for ET-OCT-V versus ET-Histo and a bias of 3.44 mu m (95% limits of agreement: -24.9 mu m to 31.78 mu m) for ET-OCT-M versus ET-Histo. Despite the strong correlation and low bias observed, the 95% limits of agreement demonstrated an unsatisfactory numerical agreement between the two OCT methods and routine histology indicating that these methods cannot be employed interchangeably. Regarding practicability, precision, and indication spectrum, ET-OCT-V and ET-OCT-M are of different clinical value. (C) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:6
相关论文
共 28 条
[1]   Histomorphologic correlation with routine histology and optical coherence tomography [J].
Bechara, FG ;
Gambichler, T ;
Stücker, M ;
Orlikov, A ;
Rotterdam, S ;
Altmeyer, P ;
Hoffmann, K .
SKIN RESEARCH AND TECHNOLOGY, 2004, 10 (03) :169-173
[2]  
Bland JM, 1996, BRIT MED J, V313, P744
[3]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Use of optical coherence tomography to monitor biological tissue freezing during cryosurgery [J].
Choi, B ;
Milner, TE ;
Kim, JH ;
Goodman, JN ;
Vargas, G ;
Aguilar, G ;
Nelson, JS .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (02) :282-286
[6]   Imaging thermally damaged tissue by polarization sensitive optical coherence tomography [J].
de Boer, JF ;
Srinivas, SM ;
Malekafzali, A ;
Chen, ZP ;
Nelson, JS .
OPTICS EXPRESS, 1998, 3 (06) :212-218
[7]   Ultrahigh-resolution optical coherence tomography [J].
Drexler, W .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :47-74
[8]  
El Gammal S, 1999, J INVEST DERMATOL, V113, P821
[9]  
Fruhstorfer H, 2000, CLIN ANAT, V13, P429, DOI 10.1002/1098-2353(2000)13:6<429::AID-CA6>3.0.CO
[10]  
2-5