Development of a high throughput in vitro toxicity screen predictive of high acute in vivo toxic potential

被引:85
作者
Evans, SM
Casartelli, A
Herreros, E
Minnick, DT
Day, C
George, E
Westmoreland, C
机构
[1] GlaxoSmithKline Res & Dev, Cellular & Biochem Toxicol Dept, Ware SG12 0DP, Herts, England
[2] GlaxoWellcome GSK Grp, Dept Safety Assessment, I-37135 Verona, Italy
[3] GlaxoSmithKline SA, Madrid 28760, Spain
[4] GlaxoSmithKline, Res Triangle Pk, NC 27709 USA
关键词
high throughput; cytotoxicity; predictive; acute in vivo toxicity; resazurin; in vitro-in vivo correlation; validation; screen; Chinese hamster ovary (CHO);
D O I
10.1016/S0887-2333(01)00064-9
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
At an early stage of drug discovery high throughput screens are an invaluable tool to de-select compounds with undesirable properties. A high throughout in vitro toxicity screen has been developed and validated to identify compounds that have a high potential to be acutely toxic in vivo. This screen is based on treating Chinese hamster ovary (CHO) cells with test compounds for 24 h and then determining the degree of cytotoxicity by the reduction of Resazurin. Twenty-six structurally unrelated compounds were chosen that spanned a range of acute LD50 values and mechanisms of toxicity. The acute LD50 values (intraperitoneal and intravenous routes) from rat and mouse were taken from the RTECS database. Experimentally derived in vitro IC35 results were compared to the 'most toxic' (lowest) LD50 values for each compound. The resulting correlation was statistically significant (r=0.8475). However, due to the scatter of the data points, it was considered not appropriate to rank compounds according to their degree of in vivo toxicity on the basis of the in vitro result. However, by defining cut-off concentrations for both the in vivo (LD50) and the in vitro (IC35) values it was possible, using the in vitro result (IC35<10<mu>M), to identify compounds that had a high potential to be acutely toxic in vivo ('most toxic' LD50 <25 <mu>mol/kg). Further development led to a high throughput screen capable of giving a 'Yes', 'No' or 'Borderline' classification as to whether a compound has a high acute in vivo toxic potential. This screen is highly specific (no false positive classifications) and has a sensitivity of approximately 80%. This is deemed acceptable for a first tier toxicity screen at an early stage in the drug discovery process. Transfer of this screen from GlaxoSmithKline UK to sites in Italy, Spain and the USA resulted in very similar findings indicating the inter-laboratory robustness of this screen and therefore the ability to compare results across the GlaxoSmithKline sites. (C) 2001 Published by Elsevier Science Ltd.
引用
收藏
页码:579 / 584
页数:6
相关论文
共 12 条
[1]  
Andrews MJ, 1997, ATLA-ALTERN LAB ANIM, V25, P641
[2]  
BALLS M, 1995, ATLA-ALTERN LAB ANIM, V23, P129
[3]  
CLOTHIER R H, 1987, Molecular Toxicology, V1, P571
[5]  
FAUTREL A, 1993, ATLA-ALTERN LAB ANIM, V21, P281
[6]  
FLINT O, 1996, IN VITRO TOXICOL, V9, P247
[7]   CORRELATION OF ACUTE LETHAL POTENCY WITH INVITRO CYTOTOXICITY [J].
FRY, JR ;
GARLE, MJ ;
HAMMOND, AH ;
HATFIELD, A .
TOXICOLOGY IN VITRO, 1990, 4 (03) :175-178
[8]  
FRY JR, 1988, ATLA-ALTERN LAB ANIM, V16, P175
[9]   IN-VITRO CYTOTOXICITY TESTS FOR THE PREDICTION OF ACUTE TOXICITY IN-VIVO [J].
GARLE, MJ ;
FENTEM, JH ;
FRY, JR .
TOXICOLOGY IN VITRO, 1994, 8 (06) :1303-1312
[10]  
PELOUX AF, 1992, ATLA-ALTERN LAB ANIM, V20, P8