Simultaneous determination of selegiline-N-oxide, a new indicator for selegiline administration, and other metabolites in urine by high-performance liquid chromatography-electrospray ionization mass spectrometry

被引:41
作者
Katagi, M [1 ]
Tatsuno, M [1 ]
Miki, A [1 ]
Nishikawa, M [1 ]
Nakajima, K [1 ]
Tsuchihashi, H [1 ]
机构
[1] Osaka Prefectural Police Headquarters, Forens Sci Lab, Chuo Ku, Osaka 5410053, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2001年 / 759卷 / 01期
关键词
selegiline; selegiline-N-oxide;
D O I
10.1016/S0378-4347(01)00213-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In order to discriminate selegiline (SG) use from methamphetamine (MA) use, the urinary metabolites of SG users have been investigated using high-performance liquid chromatography (HPLC)-electrospray ionization mass spectrometry (HPLC-ESI-MS). Selegiline-N-oxide (SGO), a specific metabolite of SG, was for the first time detected in the urine, in addition to other metabolites MA, amphetamine (AP) and desmethylselegiline (DM-SG). A combination of a Sep-pak C,, cartridge for the solid-phase extraction, a semi-micro SCX column (1.5 mm I.D.X150 mm) for HPLC separation and ESI-MS for detection provided a simple and sensitive procedure for the simultaneous determination of these analytes. Acetonitrile-10 mM ammonium formate buffer adjusted to pH 3.0 (70.30, v/v) at a flow-rate of 0.1 ml/min was found to be the most effective mobile phase. Linear calibration curves were obtained over the concentration range from 0.5 to 100 ng/ml for all the analytes by monitoring each protonated molecular ion in the selected ion monitoring (SIM) mode. The detection limits ranged from 0.1 to 0.5 ng/ml. Upon applying the scan mode, 10-20 ng/ml were the detection limits. Quantitative investigation utilizing this revealed that SGO was about three times more abundant (47 ng/ml, 79 ng/ml) than DM-SG in two SG users' urine samples tested here. This newly-detected, specific metabolite SGO was found to be an effective indicator for SG administration. (C) 2001 Elsevier Science BN. All rights reserved.
引用
收藏
页码:125 / 133
页数:9
相关论文
共 33 条
[1]   (-)DEPRENYL IN THE TREATMENT OF PARKINSONS-DISEASE [J].
BIRKMAYER, W ;
RIEDERER, P ;
YOUDIM, MBH .
CLINICAL NEUROPHARMACOLOGY, 1982, 5 (02) :195-230
[2]   Hyphenated liquid chromatographic techniques in forensic toxicology [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 733 (1-2) :65-91
[3]   AN IMPROVED PREPARATION OF TERTIARY AMINE N-OXIDES [J].
CRAIG, JC ;
PURUSHOT.KK .
JOURNAL OF ORGANIC CHEMISTRY, 1970, 35 (05) :1721-&
[4]   Studies on the Leuckart reaction [J].
Crossley, FS ;
Moore, ML .
JOURNAL OF ORGANIC CHEMISTRY, 1944, 9 (06) :529-536
[5]   THE CONTRIBUTION OF AMPHETAMINE METABOLITES OF (-)-DEPRENYL TO ITS ANTIPARKINSONIAN PROPERTIES [J].
ELSWORTH, JD ;
SANDLER, M ;
LEES, AJ ;
WARD, C ;
STERN, GM .
JOURNAL OF NEURAL TRANSMISSION, 1982, 54 (1-2) :105-110
[6]   RESOLUTION OF METHAMPHETAMINE STEREOISOMERS IN URINE DRUG-TESTING - URINARY-EXCRETION OF R(-)-METHAMPHETAMINE FOLLOWING USE OF NASAL INHALERS [J].
FITZGERALD, RL ;
RAMOS, JM ;
BOGEMA, SC ;
POKLIS, A .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (05) :255-259
[7]  
HEINONEN EH, 1989, ACTA NEUROL SCAND, V80, P93
[8]  
HEINONEN EH, 1995, ACTA NEUROL SCAND S, V8, P44
[9]   Applications of liquid chromatography mass spectrometry in analytical toxicology: A review [J].
Hoja, H ;
Marquet, P ;
Verneuil, B ;
Lotfi, H ;
Penicaut, B ;
Lachatre, G .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (02) :116-126
[10]   DETECTION OF AMPHETAMINE AND METHAMPHETAMINE IN URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY FOLLOWING DERIVATIZATION WITH (-)-MENTHYL CHLOROFORMATE [J].
HUGHES, RO ;
BRONNER, WE ;
SMITH, ML .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (05) :256-259