摘要
The present study investigated the use of a triaxial accelerometer, Tracmor2, for the measurement of physical activity in children. Eleven children [age 6.9 (2.2) years, body mass 19.5 (5.3) kg and height 112.3 (14.4) cm] were studied. Total daily energy expenditure (TDEE) was measured using the doubly labeled water method over a 2-week period. In addition, basal metabolic rate (BMR) was determined by the ventilated hood system. Physical activity level (PAL) was defined as TDEE/BMR. Tracmor2 was worn during the same 2-week period throughout waking hours after which average counts per day were calculated. The average counts per day were shown to be highly correlated to PAL values measured by doubly labeled water: PAL = 1.156x10(-5)xTracmor(2) average counts day(-1) + 0.978 (r=0.79, P<0.01). In conclusion, Tracmor2 is a valid instrument to measure physical activity in children under free-living conditions.
引用
收藏
页码:624 / 626
页数:3
相关论文
共 7 条
[1]   Daily physical activity assessment: Comparison between movement registration and doubly labeled water [J].
Bouten, CVC ;
VerboeketVandeVenne, WPHG ;
Westerterp, KR ;
Verduin, M ;
Janssen, JD .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) :1019-1026
[2]  
Ekelund U, 2001, MED SCI SPORT EXER, V33, P275
[3]   Physical activity related energy expenditure in children by doubly labeled water as compared with the Caltrac accelerometer [J].
Johnson, RK ;
Russ, J ;
Goran, MI .
INTERNATIONAL JOURNAL OF OBESITY, 1998, 22 (11) :1046-1052
[4]  
Leenders NYJM, 2001, MED SCI SPORT EXER, V33, P1233
[5]   A dual-respiration chamber system with automated calibration [J].
Schoffelen, PFM ;
Westerterp, KR ;
Saris, WHM ;
TenHoor, F .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (06) :2064-2072
[6]  
WEIR JBD, 1949, J PHYSIOL-LONDON, V109, P1, DOI 10.1113/jphysiol.1949.sp004363
[7]   THE MAASTRICHT PROTOCOL FOR THE MEASUREMENT OF BODY-COMPOSITION AND ENERGY-EXPENDITURE WITH LABELED WATER [J].
WESTERTERP, KR ;
WOUTERS, L ;
LICHTENBELT, WDV .
OBESITY RESEARCH, 1995, 3 :49-57