Stretch-activation and stretch-inactivation of Shaker-IR, a voltage-gated K+ channel

被引:82
作者
Gu, CX [1 ]
Juranka, PF [1 ]
Morris, CE [1 ]
机构
[1] Univ Ottawa, Ottawa Hosp, Dept Med, Ottawa Hlth Res Inst, Ottawa, ON K1Y 4K9, Canada
基金
加拿大自然科学与工程研究理事会; 英国医学研究理事会;
关键词
D O I
10.1016/S0006-3495(01)76237-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Mechanosensitive (MS) ion channels are ubiquitous in eukaryotic cell types but baffling because of their contentious physiologies and diverse molecular identities. In some cellular contexts mechanically responsive ion channels are undoubtedly mechanosensory transducers, but it does not follow that all MS channels are mechanotransducers. Here we demonstrate, for an archetypical voltage-gated channel (Shaker-IR; inactivation-removed), robust MS channel behavior. In oocyte patches subjected to stretch, Shaker-IR exhibits both stretch-activation (SA) and stretch-inactivation (SI), SA is seen when prestretch P-open (set by voltage) is low, and SI is seen when it is high. The stretch effects occur in cell-attached and excised patches at both macroscopic and single-channel levels. Were one ignorant of this particular MS channel's identity, one might propose it had been designed as a sophisticated reporter of bilayer tension. Knowing Shaker-IR's provenance and biology, however, such a suggestion would be absurd. We argue that the MS responses of Shaker-IR reflect not overlooked "mechano-gating" specializations of Shaker, but a common property of multiconformation membrane proteins: inherent susceptibility to bilayer tension. The molecular diversity of MS channels indicates that susceptibility to bilayer tension is hard to design out of dynamic membrane proteins. Presumably the cost of being insusceptible to bilayer tension often outweighs the benefits, especially where the in situ milieu of channels can provide mechanoprotection.
引用
收藏
页码:2678 / 2693
页数:16
相关论文
共 47 条
[1]   Channel gate! Tension, leak and disclosure [J].
Batiza, AF ;
Rayment, I ;
Kung, C .
STRUCTURE, 1999, 7 (05) :R99-R103
[2]   The voltage sensor in voltage-dependent ion channels [J].
Bezanilla, F .
PHYSIOLOGICAL REVIEWS, 2000, 80 (02) :555-592
[3]   PRESSURE-DEPENDENCE OF SODIUM GATING CURRENTS IN THE SQUID GIANT-AXON [J].
CONTI, F ;
INOUE, I ;
KUKITA, F ;
STUHMER, W .
EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 1984, 11 (02) :137-147
[4]   EFFECTS OF GADOLINIUM ON ION CHANNELS IN THE MYELINATED AXON OF XENOPUS-LAEVIS - 4 SITES OF ACTION [J].
ELINDER, F ;
ARHEM, P .
BIOPHYSICAL JOURNAL, 1994, 67 (01) :71-83
[5]   MECHANOSENSITIVE ION CHANNELS IN SKELETAL-MUSCLE FROM NORMAL AND DYSTROPHIC MICE [J].
FRANCOOBREGON, A ;
LANSMAN, JB .
JOURNAL OF PHYSIOLOGY-LONDON, 1994, 481 (02) :299-309
[6]   The nematode degenerin UNC-105 forms ion channels that are activated by degeneration- or hypercontraction-causing mutations [J].
García-Añoveros, J ;
Garcia, JA ;
Liu, JD ;
Corey, DP .
NEURON, 1998, 20 (06) :1231-1241
[7]  
Gu X. C., 1997, Biophysical Journal, V72, pA143
[8]   STRETCH-ACTIVATED SINGLE ION CHANNEL CURRENTS IN TISSUE-CULTURED EMBRYONIC CHICK SKELETAL-MUSCLE [J].
GUHARAY, F ;
SACHS, F .
JOURNAL OF PHYSIOLOGY-LONDON, 1984, 352 (JUL) :685-701
[9]   A MECHANOSENSITIVE ION CHANNEL IN THE YEAST PLASMA-MEMBRANE [J].
GUSTIN, MC ;
ZHOU, XL ;
MARTINAC, B ;
KUNG, C .
SCIENCE, 1988, 242 (4879) :762-765
[10]   Induced membrane hypo/hyper-mechanosensitivity: A limitation of patch-clamp recording [J].
Hamill, OP ;
McBride, DW .
ANNUAL REVIEW OF PHYSIOLOGY, 1997, 59 :621-631