Performance of conventional echocardiographic parameters and myocardial measurements in the sequential evaluation of left ventricular function

被引:35
作者
Hare, James L. [1 ]
Brown, Joseph K. [1 ]
Marwick, Thomas H. [1 ]
机构
[1] Univ Queensland, Brisbane, Qld, Australia
关键词
D O I
10.1016/j.amjcard.2007.10.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Echocardiography is frequently used for sequential evaluation of left ventricular (LV) function, although the reproducibility of such conventional measurements as LV ejection fraction (EF) have been questioned. The utility of such newer measurements as tissue. Doppler imaging and left atrial (LA) size in serial clinical testing are undefined. The magnitude and clinical relevance of changes in conventional and new measurements of LV. function were investigated and compared in 346 consecutive patients undergoing sequential echocardiography. Change in LA area, LVEF, tissue E velocity (Em), and transmitral E to Em ratio (E/Em) were compared over 304 +/- 239 days. Changes within and between parameters (after mean correction to make measurements comparable) were assessed in groups designated as stable (n = 144) or unstable (n = 202) according to clinical progress. A single observer remeasured these parameters in stable patients individually and with paired studies side by side. Significant variability was seen in all measurements' with change in LVEF the only parameter differing between stable and unstable groups (6.4 +/- 8.9% vs 9.4 +/- 5.4%; p < 0.001). Tissue Em and E/Em ratio were more variable than LA area or LVEF. In stable patients,,LVEF changed the least and E/Em changed the most over time.(p < 0.05). With a single blinded observer, Em had improved reproducibility (1.5 +/- 1.9 vs 2.3 +/- 2.6 cm/s; p < 0.001), as did visual EF. In conclusion, variability in all measurements was high irrespective of clinical status. Newer measurements were no better than LVEF in detecting changes in clinical status. Sequential LV assessment should be interpreted with caution, and more robust measurements are needed. (c) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:706 / 711
页数:6
相关论文
共 29 条
  • [1] Which Doppler parameters are load independent?: A study in normal volunteers after blood donation
    Abali, G
    Tokgözoglu, L
    Özcebe, OH
    Aytemir, K
    Nazli, N
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) : 1260 - 1265
  • [2] VISUAL ESTIMATION OF EJECTION FRACTION BY 2-DIMENSIONAL ECHOCARDIOGRAPHY - THE LEARNING-CURVE
    AKINBOBOYE, O
    SUMNER, J
    GOPAL, A
    KING, D
    SHEN, ZG
    BARDFELD, P
    BLANZ, L
    BROWN, EJ
    [J]. CLINICAL CARDIOLOGY, 1995, 18 (12) : 726 - 729
  • [3] Cheitlin MD, 2003, ACC AHA ASE 2003 GUI
  • [4] Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction - Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging
    Chuang, ML
    Hibberd, MG
    Salton, CJ
    Beaudin, RA
    Riley, MF
    Parker, RA
    Douglas, PS
    Manning, WJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 477 - 484
  • [5] Douglas Pamela S, 2007, J Am Coll Cardiol, V50, P187, DOI 10.1016/j.jacc.2007.05.003
  • [6] THE SEARCH FOR INTELLIGENT QUANTITATION IN ECHOCARDIOGRAPHY - EYEBALL, TRACKBALL AND BEYOND
    FOSTER, E
    CAHALAN, MK
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (03) : 848 - 850
  • [7] M-mode echocardiographic predictors at six- to seven-year incidence of coronary heart disease, stroke, congestive heart failure, and mortality in an elderly cohort (the Cardiovascular Health Study)
    Gardin, JM
    McCleland, R
    Kitzman, D
    Lima, JAC
    Bommer, W
    Klopfenstein, HS
    Wong, ND
    Smith, VE
    Gottdiener, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (09) : 1051 - 1057
  • [8] ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS
    GOPAL, AS
    SHEN, ZQ
    SAPIN, PM
    KELLER, AM
    SCHNELLBAECHER, MJ
    LEIBOWITZ, DW
    AKINBOBOYE, OO
    RODNEY, RA
    BLOOD, DK
    KING, DL
    [J]. CIRCULATION, 1995, 92 (04) : 842 - 853
  • [9] SHOULD ECHOCARDIOGRAPHY BE PERFORMED TO ASSESS EFFECTS OF ANTIHYPERTENSIVE THERAPY - TEST-RETEST RELIABILITY OF ECHOCARDIOGRAPHY FOR MEASUREMENT OF LEFT-VENTRICULAR MASS AND FUNCTION
    GOTTDIENER, JS
    LIVENGOOD, SV
    MEYER, PS
    CHASE, GA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) : 424 - 430
  • [10] Left atrial size: Renewed interest in an old echocardiographic measurement
    Gottdiener, JS
    [J]. AMERICAN HEART JOURNAL, 2004, 147 (02) : 195 - 196