Precise isotope-ratio measurements of lead species by capillary gas chromatography hyphenated to hexapole Multicollector ICP-MS

被引:39
作者
Krupp, EM
Pécheyran, C
Meffan-Main, S
Donard, OFX
机构
[1] CNRS, LCABIE, F-64053 Pau 9, France
[2] Micromass UK Ltd, Manchester M23 9LZ, Lancs, England
关键词
D O I
10.1007/s002160100778
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The precision and accuracy of lead isotope-ratio determination on a short transient signal has been assessed by coupling capillary gas chromatography to the Isoprobe (Micromass, UK), a single-focusing inductively coupled plasma mass spectrometer with multicollector detection. A T-piece connecting the GC transfer line to the torch enabled continuous aspiration of thallium solution for mass-bias correction. The volatile lead species PbEt4 was derivatized from NIST isotopic certified lead standard SRM 981 and different amounts of PbEt4 dissolved in iso-octane were injected into the GC. Chromatograms were recorded in multicollection mode by use of Faraday cups; seven isotopes (Pb-204, Pb-206, Pb-207, Pb-208, Tl-203, Tl-205, and Hg-202) were monitored simultaneously at a transient resolution of 160 ms. PbEt4 peaks were obtained with a half-width of 1.2 s and a base width of 3.5 s. Lead isotope ratios were calculated from the peak areas integrated for each lead isotope, giving precision in the range of 0.02 to 0.07% for ratios of high-abundant isotopes and injections of 5 and 50 pg absolute amount as lead (five replicates). Mass bias was found to be about 0.5% per mass unit and was corrected by using the continuously measured thallium signals at Tl-203 and Tl-205. After mass-bias correction, deviation of the certified lead ratio values was found to be in the range of 0.02 to 0.15% accuracy.
引用
收藏
页码:573 / 580
页数:8
相关论文
共 40 条
[1]   Pb and Nd isotopes in NE Atlantic Fe-Mn crusts: Proxies for trace metal paleosources and paleocean circulation [J].
Abouchami, W ;
Galer, SJG ;
Koschinsky, A .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1999, 63 (10) :1489-1505
[2]  
ABOUSAKRA F, 1999, HIGH PRECISION URANI
[3]  
ALFONSO S, 2000, THESIS U BORDEAUX 1
[4]   Measurement of lead isotope ratios in wine by ICP-MS and its applications to the determination of lead concentration by isotope dilution [J].
Augagneur, S ;
Medina, B ;
Grousset, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1149-1152
[5]   Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :921-928
[6]   Nitrogen isotopic fractionation in the synthesis of photosynthetic pigments in Rhodobacter capsulatus and Anabaena cylindrica [J].
Beaumont, VI ;
Jahnke, LL ;
Des Marais, DJ .
ORGANIC GEOCHEMISTRY, 2000, 31 (11) :1075-1085
[7]   Inorganic mass spectrometric methods for trace, ultratrace, isotope, and surface analysis [J].
Becker, JS ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :1-35
[8]   OCCURRENCE AND REDUCTION OF NOISE IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR ENHANCED PRECISION IN ISOTOPE RATIO MEASUREMENT [J].
BEGLEY, IS ;
SHARP, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :171-176
[9]  
BOWEN I, 2000, ACCURACY PRECISION I
[10]   Analytical characteristics of a high efficiency ion transmission interface (S mode) inductively coupled plasma mass spectrometer for trace element determinations in geological and environmental materials [J].
Brenner, IB ;
Liezers, M ;
Godfrey, J ;
Nelms, S ;
Cantle, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1087-1107