The Penn State safety floor: Part II - Reduction of fall-related peak impact forces on the femur

被引:29
作者
Casalena, JA
Badre-Alam, A
Ovaert, TC
Cavanagh, PR
Streit, DA [1 ]
机构
[1] Penn State Univ, Dept Mech Engn, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Kinesiol, University Pk, PA 16802 USA
[3] Penn State Univ, Dept Biobehav Sci, University Pk, PA 16802 USA
[4] Penn State Univ, Dept Med, University Pk, PA 16802 USA
[5] Penn State Univ, Dept Orthopaed, University Pk, PA 16802 USA
[6] Penn State Univ, Dept Rehabil, University Pk, PA 16802 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1998年 / 120卷 / 04期
关键词
D O I
10.1115/1.2798023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The goal of this study was to develop and validate a finite element model (FEM) for use in the design of a flooring system that would provide a stable walking surface during normal locomotion but would also deform elastically under higher lends, such as those resulting from falls. The new flooring system is designed to reduce the peak force on the femoral neck during a lateral fall onto the hip. The new flooring system is passive in nature and exhibits two distinct stiffnesses. During normal activities, the floor remains essentially rigid. Upon impact, the floor collapses and becomes a continuous walking surface. The columns were designed to remain stiff up to a significantly softer. The flooring system consists of a multitude of columns supporting specific load and, after exceeding this load, to deform elastically. The flooring returns to its original shape after impact Part I of this study presented finite element and experimental results demonstrating that the floor deflection during normal walking remained less than 2 mm. To facilitate the floor's development further, a nonlinear finite element model simulating the transient-impact response of a human hip against various floor configurations was developed. Nonlinearities included in the finite element models were: changing topology of deformable-body-to-deformable-body contact, snap-through buckling, soft tissue stiffness and damping, and large deformations. Experimental models developed for validating the finite element model included an anthropomorphic hip, an impact delivery mechanism, a data collection system, and four hand-fabricated floor files. The finite element model discussed in this study is shown to capture experimentally observed trends in peak femoral neck force reduction as a function of flooring design parameters. This study also indicates that a floor can be designed that deflects minimally during walking and reduces the peak force on the femoral neck during a fall-related impact by 15.2 percent.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 20 条
  • [1] The Penn State safety floor: Part I - Design parameters associated with walking deflections
    Casalena, JA
    Ovaert, TC
    Cavanagh, PR
    Streit, DA
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04): : 518 - 526
  • [2] EFFECTS OF LOADING RATE ON STRENGTH OF THE PROXIMAL FEMUR
    COURTNEY, AC
    WACHTEL, EF
    MYERS, ER
    HAYES, WC
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1994, 55 (01) : 53 - 58
  • [3] AGE-RELATED REDUCTIONS IN THE STRENGTH OF THE FEMUR TESTED IN A FALL-LOADING CONFIGURATION
    COURTNEY, AC
    WACHTEL, EF
    MYERS, ER
    HAYES, WC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (03) : 387 - 395
  • [4] EVANS FG, 1970, IMPACT INJURY CRASH, P402
  • [5] FRANKEL VH, 1970, IMPACT INJURY CRASH, P418
  • [6] GEHLSEN GM, 1990, ARCH PHYS MED REHAB, V71, P735
  • [7] FALL SEVERITY AND BONE-MINERAL DENSITY AS RISK-FACTORS FOR HIP FRACTURE IN AMBULATORY ELDERLY
    GREENSPAN, SL
    MYERS, ER
    MAITLAND, LA
    RESNICK, NM
    HAYES, WC
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (02): : 128 - 133
  • [8] HAYES WC, 1990, P 36 ANN M ORTH RES, P188
  • [9] JARNLO GB, 1993, CLIN ORTHOP RELAT R, V287, P41
  • [10] LAURITZEN JB, 1992, DAN MED BULL, V39, P91