A brief review of parallel magnetic resonance imaging

被引:142
作者
Heidemann, RM [1 ]
Özsarlak, Ö
Parizel, PM
Michiels, J
Kiefer, B
Jellus, V
Müller, M
Breuer, F
Blaimer, M
Griswold, MA
Jakob, PM
机构
[1] Univ Wurzburg, Dept Phys, D-97074 Wurzburg, Germany
[2] Univ Antwerp, Dept Radiol, B-2650 Edegem, Belgium
[3] Siemens Med Solut, B-1060 Brussels, Belgium
[4] Siemens Med Solut, D-91052 Erlangen, Germany
关键词
MRI; parallel imaging; thoracic; cardiac; TOF MRA; CE MRA;
D O I
10.1007/s00330-003-1992-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since the 1980s, the implementation of fast imaging methods and dedicated hardware for MRI scanners has reduced the image acquisition time from nearly an hour down to several seconds and has therefore enabled a widespread use of MRI in clinical diagnosis. Since this development, the greatest incremental gain in imaging speed has been provided by the development of parallel MRI (pMRI) techniques in late 1990s. Within the past 2 years, parallel imaging methods have become commercially available, which means that pMRI is now available for broad clinical use. In the clinical routine, virtually any MRI method can be enhanced by pMRI, allowing faster image acquisitions without any increased gradient system performance. In some cases pMRI can even result in a significant gain in image quality due to this faster acquisition. In this review article, the advantages and the disadvantages of pMRI in clinical applications are discussed and examples from many different daily applications are given.
引用
收藏
页码:2323 / 2337
页数:15
相关论文
共 40 条
[1]   Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE) [J].
Bammer, R ;
Keeling, SL ;
Augustin, M ;
Pruessmann, KP ;
Wolf, R ;
Stollberger, R ;
Hartung, HP ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :548-554
[2]   IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION [J].
CARLSON, JW ;
MINEMURA, T .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :681-688
[3]   AN ALGORITHM FOR NMR IMAGING RECONSTRUCTION BASED ON MULTIPLE RF RECEIVER COILS [J].
CARLSON, JW .
JOURNAL OF MAGNETIC RESONANCE, 1987, 74 (02) :376-380
[4]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]  
Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
[7]  
2-5
[8]  
Griswold MA, 1999, MAGNET RESON MED, V41, P1236, DOI 10.1002/(SICI)1522-2594(199906)41:6<1236::AID-MRM21>3.0.CO
[9]  
2-T
[10]  
GRISWOLD MA, 2001, P 9 SCI M ISMRM GLAS, P446