Construction of large volume monolithic columns

被引:140
作者
Podgornik, A
Barut, M
Strancar, A
Josic, D
Koloini, T
机构
[1] Univ Ljubljana, Fac Chem & Chem Technol, SI-1000 Ljubljana, Slovenia
[2] Octapharma Prod, A-1100 Vienna, Austria
[3] BIA Separat DOO, SI-1000 Ljubljana, Slovenia
关键词
D O I
10.1021/ac000680o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monolithic supports have become the subject of extensive study in the past years. Despite their advantageous features and many successful chromatographic applications in the analytical scale, only a very few examples of larger volume monoliths were described. In the case of GMA-EDMA monoliths, this can be attributed to the fact that due to the exothermic polymerization a pronounced temperature increase inside the monolith significantly affects the structure. The temperature increase depends on the thickness of the monolith, and consequently, there is an upper limit that allows the preparation of a unit with a uniform structure. In the present work, we have analyzed a heat release during the polymerization and have derived a mathematical model for the prediction of the maximal thickness of the monolithic annulus having a uniform structure. On the basis of the calculations, two annuluses of different diameters were polymerized and merged into a single monolithic unit with a volume of 80 mt. In addition, a special housing was designed to provide a uniform flow distribution in the radial direction over the entire monolith bed. It was shown that such a monolithic column exhibits now-independent separation efficiency and dynamic binding capacity up to flow rates higher than 100 mL/min. The separation and loading times are in the range of a few minutes. The pressure drop on the column is linearly dependent on the flow rate and does not exceed 2.5 MPa at a now rate of 250 mL/min.
引用
收藏
页码:5693 / 5699
页数:7
相关论文
共 40 条
[1]   CARRIER MEMBRANE AS A STATIONARY PHASE FOR AFFINITY-CHROMATOGRAPHY AND KINETIC-STUDIES OF MEMBRANE-BOUND ENZYMES [J].
ABOUREBYEH, H ;
KORBER, F ;
SCHUBERTREHBERG, K ;
REUSCH, J ;
JOSIC, D .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 566 (02) :341-350
[2]  
Amatschek K, 2000, HRC-J HIGH RES CHROM, V23, P47
[3]   High-performance membrane chromatography of supercoiled plasmid DNA [J].
Giovannini, R ;
Freitag, R ;
Tennikova, TB .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3348-3354
[4]   High performance flow injection analysis of recombinant protein G [J].
Hagedorn, J ;
Kasper, C ;
Freitag, R ;
Tennikova, T .
JOURNAL OF BIOTECHNOLOGY, 1999, 69 (01) :1-7
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[6]   APPLICATION OF HIGH-PERFORMANCE MEMBRANE CHROMATOGRAPHY FOR SEPARATION OF ANNEXINS FROM THE PLASMA-MEMBRANES OF LIVER AND ISOLATION OF MONOSPECIFIC POLYCLONAL ANTIBODIES [J].
JOSIC, D ;
LIM, YP ;
STRANCAR, A ;
REUTTER, W .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (02) :217-226
[7]   Application of membranes and compact, porous units for the separation of biopolymers [J].
Josic, D ;
Strancar, A .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (02) :333-342
[8]   Use of compact, porous units with immobilized ligands with high molecular masses in affinity chromatography and enzymatic conversion of substrates with high and low molecular masses [J].
Josic, D ;
Schwinn, H ;
Strancar, A ;
Podgornik, A ;
Barut, M ;
Lim, YP ;
Vodopivec, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :61-71
[9]   HIGH-PERFORMANCE MEMBRANE CHROMATOGRAPHY OF SERUM AND PLASMA-MEMBRANE PROTEINS [J].
JOSIC, D ;
REUSCH, J ;
LOSTER, K ;
BAUM, O ;
REUTTER, W .
JOURNAL OF CHROMATOGRAPHY, 1992, 590 (01) :59-76
[10]   Fast isolation of protein receptors from streptococci G by means of macroporous affinity discs [J].
Kasper, C ;
Meringova, L ;
Freitag, R ;
Tennikova, T .
JOURNAL OF CHROMATOGRAPHY A, 1998, 798 (1-2) :65-72