Shoulder dystocia related fetal neurological injuries: the predisposing roles of forceps and ventouse extractions

被引:7
作者
Brimacombe, Michael [2 ]
Iffy, Leslie [1 ]
Apuzzio, Joseph J. [1 ]
Varadi, Valeria [3 ]
Nagy, Balint [4 ]
Raju, Vijaya [1 ]
Portuondo, Nuris [5 ]
机构
[1] Univ Med & Dent New Jersey, New Jersey Med Sch, Dept Obstet & Gynecol, Newark, NJ 07103 USA
[2] Univ Med & Dent New Jersey, New Jersey Med Sch, Dept Prevent Med, Newark, NJ 07103 USA
[3] St Margit Hosp, Dept Pediat, Div Neonatol, Budapest, Hungary
[4] Semmelweis Univ, Sch Med, Dept Obstet & Gynaecol 1, Budapest, Hungary
[5] Law Firm Schwartz Simon Edelstein Ceslo & Kessler, Morristown, NJ USA
关键词
shoulder dystocia; forceps; ventouse; neurological birth injury; fetal macrosomia;
D O I
10.1007/s00404-007-0465-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
On the basis of 333 documented cases of permanent perinatal neurological damage, associated with arrest of the shoulders at birth, the authors conducted a retrospective study in order to evaluate the predisposing role, if any, of the utilization of extraction instruments. The investigation revealed that 35% of all injuries occurred in neonates delivered by forceps, ventouse or sequential ventouse-forceps procedures. This frequency was several-fold higher than the prevailing instrument use in the practices of American obstetricians during the same years. A high rate of forceps and ventouse extractions was demonstrable in all birth weight categories. Average weight and moderately large for gestational age fetuses underwent instrumental extractions more often than grossly macrosomic ones. This circumstance indicates that forceps and ventouse are independent risk factors, unrelated to fetal size. Their use entailed central nervous system injuries significantly more often than did spontaneous deliveries. The findings suggest that extraction procedures may be as important as macrosomia among the factors that lead to neurological damage in the child in connection with shoulder dystocia. Because they augment the intrinsic dangers of excessive fetal size exponentially, the authors consider their use in case of >= 4,000 g estimated fetal weight inadvisable. Sequential forceps-ventouse utilization further doubles the risks and is, therefore, to be avoided in all circumstances.
引用
收藏
页码:415 / 422
页数:8
相关论文
共 56 条
[1]  
ACKER DB, 1985, OBSTET GYNECOL, V66, P762
[2]  
*ACOG B, 2002, SHOULD DYST
[3]  
*ACOG COMM OP, 1998, DEL VACC EXTR
[4]  
*ACOG PRACT PATT, 1997, SHOULD DYST
[5]  
*ACOG TECHN B, 1994, OP VAG DEL
[6]  
*ACOG TECHN B, 1989, ETH DEC MAK OBST GYN
[7]  
Al Hadi M, 2001, J Obstet Gynaecol, V21, P352
[8]  
*AM AC PED AM COLL, 2002, GUID PREN CAR
[9]   Perinatally acquired brachial plexus palsy - a persisting challenge [J].
Bager, B .
ACTA PAEDIATRICA, 1997, 86 (11) :1214-1219
[10]  
BEER E, 2006, DISTOCIA DELLA SPALL, P47