Recommendations for detection and management of unsuitable samples in clinical laboratories

被引:86
作者
Lippi, Giuseppe
Banfi, Giuseppe
Buttarello, Mauro
Ceriotti, Ferruccio
Daves, Massimo
Dolci, Alberto
Caputo, Marco
Giavarina, Davide
Montagnana, Martina
Micon, Valentino
Milanesi, Bruno
Mosca, Andrea
Morandini, Margherita
Luca, Gian
机构
[1] Univ Verona, Sez Chim Clin, Dipartimento Sci Morfol Biomed, I-37134 Verona, Italy
[2] Univ Milan, Ist Galeazzi, Milan, Italy
[3] Azienda Osped Padova, Serv Med Lab, Padua, Italy
[4] Ist Sci HS Raffaele, Lab Anal, Milan, Italy
[5] Azienda Sanitaria Bolzano, Biochim Clin Lab, Bolzano, Italy
[6] Lab Anal Chim Clin, Milan, Italy
[7] Azienda Osped, Lab Patol Clin, Bussolengo, VR, Italy
[8] Osped S Bortolo, Chim Clin & Ematol Lab, Vicenza, Italy
[9] Osped Arzignano, Lab Patol Clin, Vicenza, Italy
[10] Azienda Osped, Dipartimento Med Lab, Desenzano Del Garda, BS, Italy
[11] Univ Milan, Dept Sci & Tecnol Biomed, Milan, Italy
[12] AOSMA, Lab Patol Clin, Dipartimento Med Lab, Pordenone, Italy
关键词
audit; detection of unsuitable specimens; extra-analytical variability; guidelines and consensus recommendations; laboratory errors; specimen collection;
D O I
10.1515/CCLM.2007.174
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A large body of evidence attests that quality programs developed around the analytical phase of the total testing process would only produce limited improvements, since the large majority of errors encountered in clinical laboratories still prevails within extra-analytical areas of testing, especially in manually intensive preanalytical processes. Most preanalytical errors result from system flaws and insufficient audit of the operators involved in specimen collection and handling responsibilities, leading to an unacceptable number of unsuitable specimens due to misidentification, in vitro hemolysis, clotting, inappropriate volume, wrong container or contamination from infusive routes. Detection and management of unsuitable samples are necessary to overcome this variability. The present document, issued by the Italian Inter-society SIBioC-SIMeL-CISMEL (Society of Clinical Biochemistry and Clinical Molecular Biology-Italian Society of Laboratory Medicine-Italian Committee for Standardization of Hematological and Laboratory Methods) Study Group on Extra-analytical Variability, reviews the major causes of unsuitable specimens in clinical laboratories, providing consensus recommendations for detection and management.
引用
收藏
页码:728 / 736
页数:9
相关论文
共 94 条
[1]   Minimum specimen volume requirements for routine coagulation testing - Dependence on citrate concentration [J].
Adcock, DM ;
Kressin, DC ;
Marlar, RA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 109 (05) :595-599
[2]  
*AM SOC CLIN PATH, 2006, QUAL LAB PRACT ITS R
[3]  
[Anonymous], 2001, BMC Clinical Pathology
[4]  
[Anonymous], 2005, INT TEST CLIN CHEM A
[5]  
Arkin CF, 2002, ADV LAB, V11, P33
[6]   PROBLEMS WITH MEASUREMENTS CAUSED BY HIGH-CONCENTRATIONS OF SERUM SOLIDS [J].
ARTISS, JD ;
ZAK, B .
CRC CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1987, 25 (01) :19-41
[7]  
Baer Daniel M, 2006, MLO Med Lab Obs, V38, P30
[8]   Coagulation assays [J].
Bates, SM ;
Weitz, JI .
CIRCULATION, 2005, 112 (04) :E53-E60
[9]  
Bonini P, 2002, CLIN CHEM, V48, P691
[10]  
Cantero M, 1996, CLIN CHEM, V42, P987