Rational selection of the optimum MALDI matrix for top-down proteomics by in-source decay

被引:110
作者
Demeure, Kevin [1 ]
Quinton, Loic [1 ]
Gabelica, Valerie [1 ]
De Pauw, Edwin [1 ]
机构
[1] Univ Liege, Inst Chim, CART GIGA R, Lab Spectrometrie Masse, B-4000 Cointe Ougree, Belgium
关键词
D O I
10.1021/ac070849z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
in-source decay (ISD) in MALDI leads to c- and z-fragment ion series enhanced by hydrogen radical donors and is a useful method for sequencing purified peptides and proteins. Until now, most efforts to improve methods using ISD concerned instrumental optimization. The most widely used ISD matrix is 2,5-dihydroxybenzoic acid (DHB). We present here a rational way to select MALDI matrixes likely to enhance ISD for top-down proteomic approaches. Starting from Takayama's model (Takayama, M. J. Am. Soc. Mass Spectrom. 2001, 12, 1044-9), according to which formation of ISD fragments (c and z) would be due to a transfer of hydrogen radical from the matrix to the analyte, we evaluated the hydrogen-donating capacities of matrixes, and thus their ISD abilities, with spirooxazines (hydrogen scavengers). The determined hydrogen-donating abilities of the matrixes are ranked as follows: picolinic acid (PA) > 1,5-diaminonaphtalene (1,5-DAN) > DHB > sinapinic acid > alpha-cyano-4-hydroxycinnamic acid. The ISD enhancement obtained by using 1,5-DAN compared to DHB was confirmed with peptides and proteins. On that basis, a matrix-enhanced ISD approach was successfully applied to sequence peptides and proteins up to similar to 8 kDa. Although PA alone is not suitable for peptide and protein ionization, ISD signals could be further enhanced when PA was used as an additive to 1,5-DAN. The optimized matrix preparation was successfully applied to identify larger proteins by large ISD tag researches in protein databases (BLASTp). Coupled with an adequate separation method, ISD is a promising tool to include in a top-down proteomic strategy.
引用
收藏
页码:8678 / 8685
页数:8
相关论文
共 52 条
[1]  
Azzem MA, 1996, J ELECTROANAL CHEM, V417, P163
[2]   CONTRIBUTIONS OF MASS-SPECTROMETRY TO PEPTIDE AND PROTEIN-STRUCTURE [J].
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12) :99-111
[3]   Thermodynamic control of final ion distributions in MALDI: in-plume proton transfer reactions [J].
Breuker, K ;
Knochenmuss, R ;
Zhang, J ;
Stortelder, A ;
Zenobi, R .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 226 (01) :211-222
[4]   Further studies of in-source fragmentation of peptides in matrix-assisted laser desorption-ionization [J].
Brown, RS ;
Feng, JH ;
Reiber, DC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 169 :1-18
[5]   Factors that influence the observed fast fragmentation of peptides in matrix-assisted laser desorption [J].
Brown, RS ;
Carr, BL ;
Lennon, JJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (03) :225-232
[6]   SEQUENCE-SPECIFIC FRAGMENTATION OF MATRIX-ASSISTED LASER-DESORBED PROTEIN PEPTIDE IONS [J].
BROWN, RS ;
LENNON, JJ .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :3990-3999
[7]  
Calba PJ, 1997, RAPID COMMUN MASS SP, V11, P1602, DOI 10.1002/(SICI)1097-0231(199709)11:14<1602::AID-RCM999>3.0.CO
[8]  
2-Z
[9]  
Calba PJ, 1998, RAPID COMMUN MASS SP, V12, P1727, DOI 10.1002/(SICI)1097-0231(19981130)12:22<1727::AID-RCM366>3.0.CO
[10]  
2-#