Airway wall thickness in cigarette smokers: Quantitative thin-section CT assessment

被引:115
作者
Berger, P
Perot, V
Desbarats, P
Tunon-de-Lara, JM
Marthan, R
Laurent, F [1 ]
机构
[1] Univ Victor Segalen, INSERM, E0356, Lab Physiol Cellulaire Resp, Bordeaux, France
[2] Hop Cardiol Haut Leveque, Unite Imagerie Thorac & Cardiovasc, F-33604 Pessac, France
关键词
D O I
10.1148/radiol.2353040121
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To design and validate a dedicated software tool to measure airway dimensions on thin-section computed tomographic (CT) images and to use the tool to prospectively compare airway wall thickness in nonsmokers with normal lung function with that in smokers with and without chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS: All subjects gave written informed consent. The study was approved by local ethics committee, With Laplacian of Gaussian algorithm, software was tested in phantom and excised sheep lung fixed in inflation and validated with Bland-Altman analysis. Study prospectively included nine nonsmokers (six women, three men; mean age, 53 years +/- 5.6 [standard error of the mean]) with normal lung function (group 1), seven smokers (three women, four men; mean age, 56 years +/- 5.6) with normal lung function (group 2), and eight smokers (zero women, eight men; mean age, 65 years 4.0) with COPD. Calculations were determined with spirometrically gated CT: For each selected bronchus, the wall area (WA), internal area (IA), airway caliber (sum of IA and WA), and WA/IA ratio were calculated. For each patient, summation of WA to summation of IA (Sigma WA/Sigma IA) ratio, which reflected normalized airway wall thickness, was calculated. Groups were compared by using analysis of variance with generalized linear model and unpaired t test. Pearson correlation coefficient was used to assess correlation between software measurements and pulmonary function test results. RESULTS: Comparison of measurements in phantom and excised sheep lung with algorithm measurements revealed that the latter were reliable and repeatable. In clinical study, Sigma WA/Sigma IA ratio was significantly different among three groups (P <.001). Normalized airway wall thickness and IA were significantly related to lung function test data, including forced expiratory volume in 1 second (r = -0.54, P =.006), specific airway conductance (r = -0.45, P =.03), and forced expiratory flow between 25% and 75% of vital capacity (r = -0.65, P <.001). CONCLUSION: This software provides accurate and reproducible measurements of IA and WA of bronchi on thin-section CT images and demonstrates that in vivo normalized airway wall thickness was larger in smokers with COPD than it was in smokers or nonsmokers without COPD. (c) RSNA, 2005.
引用
收藏
页码:1055 / 1064
页数:10
相关论文
共 29 条
  • [1] ASSESSMENT OF METHACHOLINE-INDUCED AIRWAY CONSTRICTION BY ULTRAFAST HIGH-RESOLUTION COMPUTED-TOMOGRAPHY
    AMIRAV, I
    KRAMER, SS
    GRUNSTEIN, MM
    HOFFMAN, EA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) : 2239 - 2250
  • [2] Subjective differentiation of normal and pathological bronchi on thin-section CT: impact of observer training
    Bankier, AA
    Fleischmann, D
    De Maertelaer, V
    Kontrus, M
    Zontsich, T
    Hittmair, K
    Mallek, R
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1999, 13 (04) : 781 - 786
  • [3] Mild intermittent asthma: CT assessment of bronchial cross-sectional area and lung attenuation at controlled lung volume
    Beigelman-Aubry, C
    Capderou, A
    Grenier, PA
    Straus, C
    Becquemin, MH
    Similowski, T
    Zelter, M
    [J]. RADIOLOGY, 2002, 223 (01) : 181 - 187
  • [4] Measurement error and correlation coefficients
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 313 (7048) : 41 - 42
  • [5] Bland JM, 1996, BRIT MED J, V313, P744
  • [6] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [7] AIRWAY RESPONSIVENESS AND BRONCHIAL-WALL THICKNESS IN ASTHMA WITH OR WITHOUT FIXED AIR-FLOW OBSTRUCTION
    BOULET, LP
    BELANGER, M
    CARRIER, G
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (03) : 865 - 871
  • [8] Individual canine airways responsiveness to aerosol histamine and methacholine in vivo
    Brown, RH
    Georgakopoulos, J
    Mitzner, W
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (02) : 491 - 497
  • [9] FAST ALGORITHMS FOR LOW-LEVEL VISION
    DERICHE, R
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) : 78 - 87
  • [10] Airflow limitation in chronic bronchitis is associated with T-lymphocyte and macrophage infiltration of the bronchial mucosa
    DiStefano, A
    Turato, G
    Maestrelli, P
    Mapp, CE
    Ruggieri, MP
    Roggeri, A
    Boschetto, P
    Fabbri, LM
    Saetta, M
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (02) : 629 - 632