Quantitative selected ion flow tube mass spectrometry: The influence of ionic diffusion and mass discrimination

被引:61
作者
Spanel, P
Smith, D
机构
[1] Keele Univ, Postgrad Med Sch, Ctr Sci & Technol Med, Stoke On Trent ST4 7QB, Staffs, England
[2] Acad Sci Czech Republ, J Heyrovsky Inst Phys Chem, V Cermak Lab, CR-18223 Prague, Czech Republic
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/S1044-0305(01)00253-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Selected ion flow tube mass spectrometry, (SIFT-MS), involves the partial conversion of mass-selected precursor ions to product ions in their reactions with the trace gases in an air sample that is introduced into helium carrier gas in a flow tube. The precursor and product ions are then detected and counted by a downstream quadrupole mass spectrometer. Quantification of particular trace gases is thus achieved from the ratio of the total count rate of the product ions to that for the precursor ions. However, it is important to appreciate that in this ion chemistry the Light precursor ions (usually H,Of ions) are invariably converted to heavier product ions. Hence, the product ions diffuse to the flow tube walls more slowly and thus they are more efficiently transported to the downstream mass spectrometer sampling orifice. This phenomenon we refer to as diffusion enhancement. Further, it is a well-known fact that discrimination can occur against ions of large mass-to-charge ratio, (m/z), in quadrupole mass spectrometers. If not accounted for, diffusion enhancement usually results in erroneously high trace gas concentrations and mass discrimination results in erroneously low concentrations. In this experimental investigation, we show how both these counteracting effects can be accounted for to increase the accuracy of SIFT-MS quantification. This is achieved by relating the currents of ions of various m/z that arrive at the downstream mass spectrometer sampling orifice disc to their count rates at the ion detector after mass analysis. Thus, both diffusion enhancement and mass discrimination are parameterized as a function of m/z and these are combined to provide an overall discrimination factor for the particular analytical instrument. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:863 / 872
页数:10
相关论文
共 43 条
[1]   Stratospheric chemical ionization mass spectrometry: nitric acid detection by different ion molecule reaction schemes [J].
Arijs, E ;
Barassin, A ;
Kopp, E ;
Amelynck, C ;
Catoire, V ;
Fink, HP ;
Guimbaud, C ;
Jenzer, U ;
Labonnette, D ;
Luithardt, W ;
Neefs, E ;
Nevejans, D ;
Schoon, N ;
Van Bavel, AM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :99-111
[2]   STRATOSPHERIC TRACE GAS-DETECTION USING A NEW BALLOON-BORNE ACIMS METHOD [J].
ARNOLD, F ;
KNOP, G .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 81 :33-44
[3]   MASS-MOBILITY CORRELATION OF IONS IN VIEW OF NEW MOBILITY DATA [J].
BERANT, Z ;
KARPAS, Z .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (11) :3819-3824
[4]   Quantitative analysis of ammonia on the breath of patients in end-stage renal failure [J].
Davies, S ;
Spanel, P ;
Smith, D .
KIDNEY INTERNATIONAL, 1997, 52 (01) :223-228
[5]  
DAWSON PH, 1969, ADV ELECT ELECT PHYS, V39, P60
[6]   Measured and calculated mobilities of cluster ions drifting in helium and in nitrogen [J].
de Gouw, JA ;
Krishnamurthy, M ;
Bierbaum, VM ;
Leone, SR .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 167 :281-289
[7]   Proton-transfer chemical-ionization mass spectrometry allows real-time analysis of volatile organic compounds released from cutting and drying of crops [J].
De Gouw, JA ;
Howard, CJ ;
Custer, TG ;
Baker, BM ;
Fall, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (12) :2640-2648
[8]  
Ellis H. W., 1978, Atomic Data and Nuclear Data Tables, V22, P179, DOI 10.1016/0092-640X(78)90014-1
[9]  
Ellis H. W., 1976, Atomic Data and Nuclear Data Tables, V17, P177, DOI 10.1016/0092-640X(76)90001-2
[10]  
Harrison A.G., 1992, CHEM IONISATION MASS