Comparison of the Spreeta® surface plasmon resonance sensor and a quartz crystal microbalance for detection of Escherichia coli heat-labile enterotoxin

被引:67
作者
Spangler, BD [1 ]
Wilkinson, EA
Murphy, JT
Tyler, BJ
机构
[1] Montana State Univ, Dept Chem & Biochem, Bozeman, MT 59717 USA
[2] Montana State Univ, Dept Chem Engn, Bozeman, MT 59717 USA
关键词
biosensor; pathogenic agent detection; quartz crystal microbalance (QCM); surface plasmon resonance (SPR); Escherichia coli; heat-labile enterotoxin;
D O I
10.1016/S0003-2670(01)01156-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Small, low-cost sensors that rapidly detect pathogens or their toxic products in food and water supplies would facilitate environmental monitoring. However, they must be sufficiently easy to use and reliable enough to be widely deployed. In this study, a small surface plasmon resonance sensor (Spreeta((R)) SPR) and a quartz crystal microbalance (QCM) have been evaluated to determine whether the sensitivity, reliability, and ease of operation of one or both devices would be suitable for flow-cell format detection of pathogenic agents. Both make use of a gold-coated surface modified by deposition of a suitable capture agent. In each case, analyte binding to the capture agent results in a quantifiable signal. The model system consisted of Escherichia coli heat-labile enterotoxin (LT), responsible for travelers' diarrhea, and its receptor analog, ganglioside GM(1). Each device provided a roughly proportional response in a range between 3 (35 pmol) and 25 mug (300 pmol) of toxin protein, but began to saturate the adlayer of capture agent at higher toxin concentrations. The Spreeta((R)) SPR produced a significant response to 6 mug (70 pmol) of E. coli enterotoxin, while the QCM device produced a measurable response to 3 mug (35 pmol) of E. coli enterotoxin. The two devices are comparable with respect to ease of operation and reliability. Both devices could be suitable for remote sensing of analyte from a flow stream with suitable enclosures and temperature-controlled buffering to prevent artifacts induced by temperature fluctuation. There appear to be no significant differences between the Spreeta((R)) SPR device compared to a QCM device as a small, low-cost, rapid biodetector. While neither device matches the sensitivity of enzyme-linked immunosorbant assay(ELISA) for detection of picograms amounts of analyte, measurements can be obtained directly, in minutes, rather than the hours required to visualize results of an ELISA. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 161
页数:13
相关论文
共 32 条
[1]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR
[2]   Theoretical analysis of protein concentration determination using biosensor technology under conditions of partial mass transport limitation [J].
Christensen, LLH .
ANALYTICAL BIOCHEMISTRY, 1997, 249 (02) :153-164
[3]   Integrated analytical sensors: the use of the TISPR-1 as a biosensor [J].
Elkind, JL ;
Stimpson, DI ;
Strong, AA ;
Bartholomew, DU ;
Melendez, JL .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :182-190
[4]   QCM response to solvated, tethered macromolecules [J].
Fawcett, NC ;
Craven, RD ;
Zhang, P ;
Evans, JA .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2876-2880
[5]   SURFACE-PLASMON RESONANCE AND IMMUNOSENSORS [J].
FLANAGAN, MT ;
PANTELL, RH .
ELECTRONICS LETTERS, 1984, 20 (23) :968-970
[6]   ROLE OF TRYPSIN-LIKE CLEAVAGE AT ARGININE-192 IN THE ENZYMATIC AND CYTOTONIC ACTIVITIES OF ESCHERICHIA-COLI HEAT-LABILE ENTEROTOXIN [J].
GRANT, CCR ;
MESSER, RJ ;
CIEPLAK, W .
INFECTION AND IMMUNITY, 1994, 62 (10) :4270-4278
[7]   DETERMINATION OF PARTITION-COEFFICIENTS FROM SURFACE ACOUSTIC-WAVE VAPOR SENSOR RESPONSES AND CORRELATION WITH GAS-LIQUID CHROMATOGRAPHIC PARTITION-COEFFICIENTS [J].
GRATE, JW ;
SNOW, A ;
BALLANTINE, DS ;
WOHLTJEN, H ;
ABRAHAM, MH ;
MCGILL, RA ;
SASSON, P .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :869-875
[8]   CHARACTERIZATION OF POLY-L-LYSINE ADSORPTION ONTO ALKANETHIOL-MODIFIED GOLD SURFACES WITH POLARIZATION-MODULATION FOURIER-TRANSFORM INFRARED-SPECTROSCOPY AND SURFACE-PLASMON RESONANCE MEASUREMENTS [J].
JORDAN, CE ;
FREY, BL ;
KORNGUTH, S ;
CORN, RM .
LANGMUIR, 1994, 10 (10) :3642-3648
[9]   Surface plasmon resonance imaging measurements of electrostatic biopolymer adsorption onto chemically modified gold surfaces [J].
Jordan, CE ;
Corn, RM .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1449-1456
[10]  
JOSEPH JP, 1993, SENSORS, P1