Validation of the acetylene rebreathing method for measurement of cardiac output at rest and during high-intensity exercise

被引:41
作者
Liu, Y [1 ]
Menold, E [1 ]
Dullenkopf, A [1 ]
Reissnecker, S [1 ]
Lormes, W [1 ]
Lehmann, M [1 ]
Steinacker, JM [1 ]
机构
[1] UNIV ULM,ABT SPORT & LEISTUNGSMED,D-89070 ULM,GERMANY
来源
CLINICAL PHYSIOLOGY | 1997年 / 17卷 / 02期
关键词
Douglas bag; Fick method; mass spectrometry; oxygen uptake; work rate;
D O I
10.1046/j.1365-2281.1997.02323.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The use of the acetylene rebreathing method to estimate cardiac output (GO) during high-intensity exercise, which may be influenced by recirculation of acetylene, has not been validated. This study was designed to validate the acetylene rebreathing method to measure CO during high-intensity exercise using the direct Fick method. CO was measured at rest and during exercise at 25%, 50%, 75% and 90% of the nine subjects' maximum oxygen up take (Vo(2max)) by the direct Fick and acetylene rebreathing method. CO measured by the acetylene rebreathing method correlated with work rate (r=0.90, P<0.01) and with oxygen uptake (r=0.94, P<0.01). The correlation coefficient of CO between both methods was r=0.91 (P<0.01). There was no significant difference in CO measured by each method at rest as well as at each, work rate. The difference in CO between each method was greater at lower CO than at higher CO. At 90 % of Vo(2max), the CO measured by acetylene rebreathing was nearly identical to that measured by the Fick method. It can be concluded that acetylene rebreathing for measurement of CO is valid not only at rest but also during exercise, especially during high-intensity exercise.
引用
收藏
页码:171 / 182
页数:12
相关论文
共 36 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
BAUMANN HANS, 1930, ZEITSCHR KLIN MED, V115, P41
[3]  
BONDEPETERSEN F, 1980, AVIAT SPACE ENVIR MD, V51, P1214
[4]   NONINVASIVE ESTIMATION OF CARDIAC-OUTPUT WITH NONPRESCRIBED BREATHING [J].
CABRERA, ME ;
SAIDEL, GM ;
COHEN, MH .
ANNALS OF BIOMEDICAL ENGINEERING, 1991, 19 (06) :723-742
[5]   SIMULTANEOUS DETERMINATIONS OF THE RESTING ARTERIOVENOUS OXYGEN DIFFERENCE BY THE ACETYLENE AND DIRECT FICK METHODS [J].
CHAPMAN, CB ;
TAYLOR, HL ;
BORDEN, C ;
EBERT, RV ;
KEYS, A ;
CARLSON, WS .
JOURNAL OF CLINICAL INVESTIGATION, 1950, 29 (06) :651-659
[6]   COMPARISON OF CARDIAC-OUTPUT MEASUREMENT TECHNIQUES - THERMODILUTION, DOPPLER, CO2-REBREATHING AND THE DIRECT FICK METHOD [J].
ESPERSEN, K ;
JENSEN, EW ;
ROSENBORG, D ;
THOMSEN, JK ;
ELIASEN, K ;
OLSEN, NV ;
KANSTRUP, IL .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (02) :245-251
[7]   CARDIAC-OUTPUT DETERMINATION BY SIMPLE ONE-STEP REBREATHING TECHNIQUE [J].
FARHI, LE ;
NESARAJAH, MS ;
OLSZOWKA, AJ ;
METILDI, LA ;
ELLIS, AK .
RESPIRATION PHYSIOLOGY, 1976, 28 (01) :141-159
[8]   MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD [J].
FEGLER, G .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1954, 39 (03) :153-164
[9]   The determination of the cardiac output of man by the use of acetylene [J].
Grollman, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1929, 88 (03) :432-445
[10]   REGIONAL DISTRIBUTION OF VA-Q IN MAN AT REST AND WITH EXERCISE MEASURED WITH KRYPTON-81M [J].
HARF, A ;
PRATT, T ;
HUGHES, JMB .
JOURNAL OF APPLIED PHYSIOLOGY, 1978, 44 (01) :115-123