Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices

被引:74
作者
Valencia, R [1 ]
Denecke, T [1 ]
Lehmkuhl, L [1 ]
Fischbach, F [1 ]
Felix, R [1 ]
Knollmann, F [1 ]
机构
[1] Charite Univ Med Berlin, Klin Strahlenheilkunde, Berlin, Germany
关键词
maximum intensity projection; MIP; pulmonary nodule; thoracic CT; multislice computed tomography;
D O I
10.1007/s00330-005-2871-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the diagnostic accuracy of non-overlapping 10-mm axial and coronal maximum intensity projections (MIP) in comparison with standard axial 1-mm and 5-mm slices in the detection of pulmonary nodules. Sixty patients with suspected nodules who underwent multislice spiral CT of the chest were evaluated. Axial 1-mm and 5-mm slices as well as non-overlapping 10-mm axial/coronal MIPs were interpreted independently by three blinded radiologists. After initial review, a retrospective consensus session was performed for agreement on final nodule counts using the axial 1-mm slices as gold standard. Small nodules of less than 5 mm in size were most accurately detected by the axial MIPs. Receiver operating characteristic (ROC) analysis of these small nodules showed that 5-mm slices were not capable of a statistically significant differentiation of nodules from other focal lesions in two observers (p=0.034 and p=0.012, respectively) whereas 1-mm slices and coronal/axial MIPs did allow a statistically significant differentiation in all observers (p < 0.001). Nodules larger than 5 mm were equally well depicted with all modalities. Non-overlapping 10-mm axial MIPs improve the accuracy in the detection of small pulmonary nodules.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 26 条
[1]   Lung image database consortium: Developing a resource for the medical imaging research community [J].
Armato, SG ;
McLennan, G ;
McNitt-Gray, MF ;
Meyer, CR ;
Yankelevitz, D ;
Aberle, DR ;
Henschke, CI ;
Hoffman, EA ;
Kazerooni, EA ;
MacMahon, H ;
Reeves, AP ;
Croft, BY ;
Clarke, LP .
RADIOLOGY, 2004, 232 (03) :739-748
[2]   Glossary of terms for CT of the lungs: Recommendations of the Nomenclature Committee of the Fleischner Society [J].
Austin, JHM ;
Muller, NL ;
Friedman, PJ ;
Hansell, DM ;
Naidich, DP ;
RemyJardin, M ;
Webb, WR ;
Zerhouni, EA .
RADIOLOGY, 1996, 200 (02) :327-331
[3]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[4]   Small pulmonary nodules: Detection at chest CT and outcome [J].
Benjamin, MS ;
Drucker, EA ;
McLoud, TC ;
Shepard, JAO .
RADIOLOGY, 2003, 226 (02) :489-493
[5]   Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT [J].
Coakley, FV ;
Cohen, MD ;
Johnson, MS ;
Gonin, R ;
Hanna, MP .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842) :135-140
[6]   Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[7]   Helical CT of pulmonary modules in patients with extrathoracic malignancy: CT - Surgical correlation [J].
Diederich, S ;
Semik, M ;
Lentschig, MG ;
Winter, F ;
Scheld, HH ;
Roos, N ;
Bongartz, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (02) :353-360
[8]   Detection of pulmonary nodules at spiral CT: comparison of maximum intensity projection sliding slabs and single-image reporting [J].
Diederich, S ;
Lentschig, MG ;
Overbeck, TR ;
Wormanns, D ;
Heindel, W .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1345-1350
[9]   Multidetector-row CT of the lungs:: Multiplanar reconstructions and maximum intensity projections for the detection of pulmonary nodules. [J].
Eibel, R ;
Türk, TR ;
Kulinna, C ;
Herrmann, K ;
Reiser, MF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (09) :815-821
[10]   Value of multiplanar reformations (MPR) in multislice spiral CT. [J].
Eibel, R ;
Türk, T ;
Kulinna, C ;
Schöpf, UJ ;
Brüning, R ;
Reiser, MF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (01) :57-64