Optimisation of target plates for the W7-X divertor at stationary operation

被引:3
作者
Boscary, J [1 ]
Greuner, H [1 ]
Hoffmann, FW [1 ]
Mendelevitch, B [1 ]
Pfefferle, K [1 ]
Renner, H [1 ]
机构
[1] EURATOM, Teilinst Greifswald, Max Planck Inst Plasmaphys, D-17491 Greifswald, Germany
关键词
wendelstein; 7-X; divertor; plasma facing component; target plates;
D O I
10.1016/S0920-3796(01)00300-3
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The open divertor structure of the Wendelstein 7-X stellarator allows an effective particle and energy exhaust for a wide range of plasma and magnetic parameters. Ten 3D-shaped surfaces are located along the helical edge of the five-fold rotational symmetry magnetic configuration of the machine. The plasma outflow concentrates onto the target plates, so that the plasma is decoupled from the wall. The target plates are designed to withstand a maximum stationary heat flux of 10 MW/m(2). The present optimised design of the target plates, which takes into account the latest results of the physics, the requirements of the heatings and diagnostics systems, the manufacturing costs and the mounting operations in order to build a technical reliable system is presented. (C) 2001 Elsevier Science BN. All rights reserved.
引用
收藏
页码:279 / 283
页数:5
相关论文
共 5 条
[1]  
GREUNER H, 1996, P 19 SOFT, P249
[2]  
GREUNER H, IN PRESS THERMAL HYD
[3]  
REHM H, 2000, MICROGRAPHIC EXAMINA
[4]   The capabilities of steady state operation at the stellarator W7-X with emphasis on divertor design [J].
Renner, H ;
Boscary, J ;
Erckmann, V ;
Greuner, H ;
Grote, H ;
Sapper, J ;
Speth, E ;
Wesner, F ;
Wanner, M .
NUCLEAR FUSION, 2000, 40 (06) :1083-1093
[5]  