Influence of antibody valency in a displacement immunoassay for the quantitation of 2,4-dichlorophenoxyacetic acid

被引:13
作者
Gerdes, M
Meusel, M
Spener, F
机构
[1] Inst Chemo & Biosensorik, D-48149 Munster, Germany
[2] Univ Munster, Inst Biochem, D-48149 Munster, Germany
关键词
antibody valency; fab-fragment; 2,4-dichlorophenoxyacetic acid (2,4-D); 2-methyl-4-chlorophenoxyacetic acid (MCPA); displacement assay; rapid assay;
D O I
10.1016/S0022-1759(98)00211-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The influence of antibody valency in a displacement immunoassay was investigated by comparing the whole antibody molecule with the corresponding Fab-fragment. The displacement immunoassay for the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) takes advantage of the cross-reactivity of monoclonal anti-2,4-D antibodies and the Fab-fragments toward immobilized 2-methyl-4-chlorophenoxyacetic acid (MCPA). Due to the low affinity of the antibodies toward MCPA (cross-reactivity of approximately 30%), the addition of 2,4-D resulted in a displacement of the antibodies or the fragments. The detection limits obtained with whole anti-2,4-D antibodies and Fab-fragments were 0.1 mu g/l and 0.01 mu g/l 2,4-D, respectively. The whole antibodies and the Fab-fragments show similarities, such as the cross-reactivity toward MCPA (26% and 33%), and some characteristics of the calibration curve, for example the large detection range and the sensitivity. In contrast to the bivalent antibodies, however, increasing the hapten/protein ratios of the immobilized MCPA-BSA conjugates did not affect the detection limit when using the Fab-fragments. Moreover, kinetic experiments reveal a faster displacement reaction with the Fab-fragments. A disadvantage of using the Fab-fragments is the generation of lower absorbance values in the ELISA. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 226
页数:10
相关论文
共 35 条
[1]   SCREENING AND KINETIC-ANALYSIS OF RECOMBINANT ANTI-CEA ANTIBODY FRAGMENTS [J].
ABRAHAM, R ;
BUXBAUM, S ;
LINK, J ;
SMITH, R ;
VENTI, C ;
DARSLEY, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 183 (01) :119-125
[2]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[3]   BIOCHEMICAL ASPECTS OF BIOSENSORS [J].
BYFIELD, MP ;
ABUKNESHA, RA .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (4-5) :373-400
[4]   INFLUENCE OF POLYVALENCY ON BINDING PROPERTIES OF ANTIBODIES [J].
CROTHERS, DM ;
METZGER, H .
IMMUNOCHEMISTRY, 1972, 9 (03) :341-+
[5]  
DOERFFEL K, 1994, ANALYTIKUM
[6]   Electrochemical immunosensors for determination of the pesticides 2,4-dichlorophenoxyacetic and 2,4,5-trichlorophenoxyacetic acids [J].
Dzantiev, BB ;
Zherdev, AV ;
Yulaev, MF ;
Sitdikov, RA ;
Dmitrieva, NM ;
Moreva, IY .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :179-185
[7]   Microformat imaging ELISA for pesticide determination [J].
Dzgoev, A ;
Mecklenburg, M ;
Larsson, PO ;
Danielsson, B .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3364-3369
[8]   MONOCLONAL ELISA FOR 2,4-DICHLOROPHENOXYACETIC ACID - CHARACTERIZATION OF ANTIBODIES AND ASSAY OPTIMIZATION [J].
FRANEK, M ;
KOLAR, V ;
GRANATOVA, M ;
NEVORANKOVA, Z .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (06) :1369-1374
[9]  
GEE SJ, 1994, USERS GUIDE ENV IMMU
[10]   Development of a displacement immunoassay by exploiting cross-reactivity of a monoclonal antibody [J].
Gerdes, M ;
Meusel, M ;
Spencer, F .
ANALYTICAL BIOCHEMISTRY, 1997, 252 (01) :198-204