Accurate measurement of avidin and streptavidin in crude biofluids with a new, optimized biotin-fluorescein conjugate

被引:125
作者
Kada, G
Falk, H
Gruber, HJ
机构
[1] Johannes Kepler Univ Linz, Inst Biophys, A-4040 Linz, Austria
[2] Johannes Kepler Univ Linz, Inst Chem, A-4040 Linz, Austria
来源
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS | 1999年 / 1427卷 / 01期
关键词
avidin; biotin; fluorescein; fluorescence; streptavidin;
D O I
10.1016/S0304-4165(98)00178-0
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new biotin-fluorescein conjugate with an ethylene diamine spacer was found to be the first fluorescent biotin derivative which truly mimicked D-biotin in terms of high affinity, fast association, and non-cooperative binding to avidin and streptavidin tetramers, These exceptional properties were attributed to the small size/length of the new ligand since all larger/ longer biotin derivatives are known for their mutual steric hindrance and anti-cooperative binding in 4:1 complexes with avidin and streptavidin tetramers. Specific binding of the new biotin-fluorescein conjugate towards avidin and streptavidin was accompanied by 84-88% quenching of ligand fluorescence. In the accompanying study this effect was used for rapid estimation of avidin and streptavidin in a new 'single tube assay'. In the present study the strong quenching effect was utilized to accurately monitor stoichiometric titration of biotin-binding sites in samples with greater than or equal to 200 pM avidin or streptavidin. The concentration was calculated from the consumption of fluorescent ligand up to the distinct breakpoint in the fluorescence titration profile which was marked by the abrupt appearance of strongly fluorescent ligands which were in excess. Due to this protocol the assay was not perturbed by background fluorescence or coloration in the unknown samples. The new fluorescence titration assay is particularly suited for quick checks on short notice because getting started only means to thaw an aliquot of a standardized stock solution of fluorescent ligand. No calibration is required for the individual assay and the ligand stock solution needs to be restandardized once per week (or once per year) when stored at -25 degrees C (or at -70 degrees C, respectively). (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:33 / 43
页数:11
相关论文
共 37 条
[1]   FLUORIMETRIC ASSAYS FOR AVIDIN AND BIOTIN BASED ON BIOTIN-INDUCED FLUORESCENCE ENHANCEMENT OF FLUORESCEIN-LABELED AVIDIN [J].
ALHAKIEM, MHH ;
LANDON, J ;
SMITH, DS ;
NARGESSI, RD .
ANALYTICAL BIOCHEMISTRY, 1981, 116 (02) :264-267
[2]   ENHANCEMENT OF THE EMISSION INTENSITY OF FLUOROPHORE-LABELED AVIDIN BY BIOTIN AND BIOTIN DERIVATIVES - EVALUATION OF DIFFERENT FLUOROPHORES FOR IMPROVED SENSITIVITY [J].
BARBARAKIS, MS ;
SMITHPALMER, T ;
BACHAS, LG ;
CHEN, SY ;
VANDERMEER, BW .
TALANTA, 1993, 40 (07) :1139-1145
[3]   OBSERVATION OF HOOK EFFECTS IN THE INHIBITION AND DOSE-RESPONSE CURVES OF BIOTIN ASSAYS BASED ON THE INTERACTION OF BIOTINYLATED GLUCOSE-OXIDASE WITH (STREPT)AVIDIN [J].
BARBARAKIS, MS ;
QAISI, WG ;
DAUNERT, S ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :457-460
[4]  
BAYER EA, 1990, METHOD ENZYMOL, V184, P217
[5]  
FELDHOFF R, 1991, TECH PROTEIN CHEM, V17, P55
[6]  
FINN FM, 1980, J BIOL CHEM, V255, P5742
[7]   LIGANDS FOR INSULIN-RECEPTOR ISOLATION [J].
FINN, FM ;
TITUS, G ;
HOFMANN, K .
BIOCHEMISTRY, 1984, 23 (12) :2554-2558
[8]  
FINN FM, 1985, METHOD ENZYMOL, V109, P418
[9]  
GREEN N. M., 1970, Methods in Enzymology, V18A, P418, DOI 10.1016/0076-6879(71)18342-5
[10]  
Green N M, 1975, Adv Protein Chem, V29, P85, DOI 10.1016/S0065-3233(08)60411-8