Assessing the accuracy of analytical methods using linear regression with errors in both axes

被引:114
作者
Riu, J
Rius, FX
机构
[1] Departament de Qúimica, Universitat Rovira i Virgili, 43005-Tarragona, Catalonia, Pl. Imperial Tarraco
关键词
D O I
10.1021/ac951217s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a new technique for assessing the accuracy of analytical methods using linear regression is reported, The results of newly developed analytical methods are regressed against the results obtained using reference methods, The new test is based on the joint confidence interval for the slope and the intercept of the regression line, which is calculated taking the uncertainties in both axes into account, The slope, intercept, and variances which are associated with the regression coefficients are calculated with bivariate least-squares regression (BLS), The new technique was validated using three simulated and five real data sets, The Monte Carlo method was applied to obtain 100 000 data sets for each of the initial simulated data sets to show the correctness of the new technique, The application of the new technique to five real data sets enables differences to be detected between the results of the joint confidence interval based on the BLS method and the results of the commonly used tests based on ordinary least-squares or weighted least-squares regression.
引用
收藏
页码:1851 / 1857
页数:7
相关论文
共 19 条
[1]   STRAIGHT-LINE CALIBRATION - SOMETHING MORE THAN SLOPES, INTERCEPTS, AND CORRELATION-COEFFICIENTS [J].
BOQUE, R ;
RIUS, FX ;
MASSART, DL .
JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (03) :230-232
[2]  
DELAGUARDIA M, 1980, AN QUIM, V77, P129
[3]  
DRAPER N, 1981, APPL REGRESSION ANAL, P5
[4]   INFRARED REFLECTION-ABSORPTION SPECTROSCOPY OF PHOTORESIST FILMS ON SILICON-WAFERS - MEASURING FILM THICKNESS AND REMOVING INTERFERENCE-FRINGES [J].
GAMSKY, CJ ;
HOWES, GR ;
TAYLOR, JW .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1015-1020
[5]  
GUELL O, 1990, ANAL CHEM, V60, pA529
[6]   ROLE OF MODIFIERS FOR ANALYTICAL-SCALE SUPERCRITICAL-FLUID EXTRACTION OF ENVIRONMENTAL-SAMPLES [J].
LANGENFELD, JJ ;
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (06) :909-916
[7]   MULTIPLE STRAIGHT-LINE LEAST-SQUARES ANALYSIS WITH UNCERTAINTIES IN ALL VARIABLES [J].
LISY, JM ;
CHOLVADOVA, A ;
KUTEJ, J .
COMPUTERS & CHEMISTRY, 1990, 14 (03) :189-192
[8]   MICROWAVE-ASSISTED EXTRACTION OF ORGANIC-COMPOUNDS FROM STANDARD REFERENCE SOILS AND SEDIMENTS [J].
LOPEZAVILA, V ;
YOUNG, R ;
BECKERT, WF .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1097-1106
[9]   STUDY OF ACCURACY IN CHEMICAL ANALYSIS USING LINEAR CALIBRATION CURVES [J].
MANDEL, J ;
LINNIG, FJ .
ANALYTICAL CHEMISTRY, 1957, 29 (05) :743-749
[10]  
MEIER PC, 1993, STAT METHODS ANAL CH, P145