Resynchronization pacing is a useful adjunct to the management of acute heart failure after surgery for congenital heart defects

被引:80
作者
Janousek, J [1 ]
Vojtovic, P [1 ]
Hucín, B [1 ]
Tláskal, T [1 ]
Gebauer, RA [1 ]
Gebauer, R [1 ]
Matejka, T [1 ]
Marek, J [1 ]
Reich, O [1 ]
机构
[1] Univ Hosp Motor, Kardio Ctr, Prague 15006, Czech Republic
关键词
D O I
10.1016/S0002-9149(01)01609-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The acute hemodynamic effect of atrioventricular (AV) and inter/intraventricular (IV) resynchronization accomplished by temporary pacing using multiple epicardial pacing wires was evaluated in 20 children (aged 3.4 months to 14.0 years) after surgery for congenital heart defects Fulfilling the following criteria: (1) presence of AV and/or IV conduction delay, and (2) need for inotropic support. AV resynchronization in = 13) was achieved by AV delay optimization during atrial synchronous right ventricular outflow tract pacing. IV resynchronization (n = 14) wets accomplished by atrial synchronous pacing from the right ventricular lateral wall in 7 patients with right bundle branch block and normal AV conduction and by atrial synchronous multisite ventricular pacing in another 7 patients with previously performed AV resynchronization. Compared with baseline values, AV resynchronization resulted in an increase in arterial systolic, mean, and pulse pressures by 7.2 +/- 8.3% (p <0.01), 8.6 +/- 8.1% (p < 0.005), and 6.9 +/- 13.5% (p = NS), respectively. IV resynchronization used either alone or added to previously performed AV resynchronization led to a pressure increase of 7.0 a 4.7%, 5.9 +/- 4.7%, and 9.4 +/- 7.8%, respectively (p < 0.001 For oil). The combined effect of AV and IV resynchronization resulted in a systolic, mean, and pulse pressure increase of 10.2 +/- 5.0% (range 4.0 to 19.1), 8.6 +/- 5.4% (range 0.8 to 14.8), and 15.2 +/- 8.5% (range 6.1 to 33.3), respectively (p < 0.001 for all). The increase in systolic arterial pressure after IV resynchronization was positively correlated with the initial QRS duration (r = 0.62, p < 0.05) and extent of QRS shortening (r = 0.66, p < 0.05). In conclusion, resynchronization pacing led to a significant increase in arterial blood pressure and was a useful adjunct to the treatment of acute postoperative heart failure in patients with AV and/or IV conduction delay. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 23 条
  • [1] Electrocardiographic predictive factors of long-term clinical improvement with multisite biventricular pacing in advanced heart failure
    Alonso, C
    Leclercq, C
    Victor, F
    Mansour, H
    de Place, C
    Pavin, D
    Carré, F
    Mabo, P
    Daubert, JC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (12) : 1417 - 1421
  • [2] Auricchio A, 1999, AM J CARDIOL, V83, p130D
  • [3] Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure
    Auricchio, A
    Stellbrink, C
    Block, M
    Sack, S
    Vogt, J
    Bakker, P
    Klein, H
    Kramer, A
    Ding, J
    Salo, R
    Tockman, B
    Pochet, T
    Spinelli, J
    [J]. CIRCULATION, 1999, 99 (23) : 2993 - 3001
  • [4] Auricchio A, 1999, AM J CARDIOL, V83, p136D
  • [5] Blanc JJ, 1997, CIRCULATION, V96, P3273
  • [6] EFFECTS OF DUAL-CHAMBER PACING WITH SHORT ATRIOVENTRICULAR DELAY IN DILATED CARDIOMYOPATHY
    BRECKER, SJD
    XIAO, HB
    SPARROW, J
    GIBSON, DG
    [J]. LANCET, 1992, 340 (8831) : 1308 - 1312
  • [7] Acute hemodynamic effects of alternate and combined site pacing in patients after cardiac surgery
    Buckingham, TA
    Candinas, R
    Duru, F
    Pagotto, E
    Schönbeck, M
    Amann, FW
    Turina, M
    Schmid, ER
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (06): : 887 - 893
  • [8] Multisite pacing for end-stage heart failure: Early experience
    Cazeau, S
    Ritter, P
    Lazarus, A
    Gras, D
    Backdach, H
    Mundler, O
    Mugica, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1748 - 1757
  • [9] Permanent left ventricular pacing with transvenous leads inserted into the coronary veins
    Daubert, JC
    Ritter, P
    Le Breton, H
    Gras, D
    LeClercq, C
    Lazarus, A
    Mugica, J
    Mabo, P
    Cazeau, S
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01): : 239 - 245
  • [10] de Cock CC, 1998, PACE, V21, P536, DOI 10.1111/j.1540-8159.1998.tb00095.x