Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry

被引:63
作者
Gerhardt, GA
Hoffman, AF
机构
[1] Univ Kentucky, Dept Anat & Neurobiol, Chandler Med Ctr, Lexington, KY 40536 USA
[2] Univ Kentucky, Morris K Udall Parkinsons Dis Res Ctr Excellence, Chandler Med Ctr, Lexington, KY 40536 USA
[3] NIDA, Cellular Neurobiol Branch, Intramural Res Program, NIH, Baltimore, MD USA
关键词
dopamine; serotonin; norepinephrine; nafion-coated microelectrodes; chronoamperometry;
D O I
10.1016/S0165-0270(01)00396-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present study concerns methodological issues of electrochemical recordings using Nafion-coated 30 mum diameter single carbon fiber microelectrodes for high-speed chronoamperometric measurements of biogenic amines. First, the single carbon fiber microelectrodes were coated with Nafion and dried at 85 vs. 200 degreesC and their recording properties were determined. Second, the effects of shifts in solution pH, ionic strength, changes in recording solution levels of Ca2+ or Mg2+ and temperature on the recording characteristics and sensitivity of Nafion-coated high temperature dried (200 degreesC) single carbon fiber microelectrodes for measures of dopamine were studied. These studies showed that the high temperature drying of the Nafion produced a microelectrode with better recording properties: higher selectivity for cations versus anions, increased differences between the reduction and oxidation current ratios for the identification of dopamine versus serotonin, and more rapid response times. In addition, these studies demonstrated that the chronoamperometric recordings were insensitive to small changes in pH and divalent cations such as Ca2+ or Mg2+. However, increases in ionic strength decreased the sensitivity of the microelectrodes, while increases in temperature produced increases in the sensitivity of the microelectrodes for biogenic amines. These data support that Nafion-coated high temperature (200 degreesC) dried microelectrodes have enhanced recording properties as compared to microelectrodes, which are coated with Nafion and dried at 85 degreesC. In addition, high-speed chronoamperometric. recordings of biogenic. amines are not affected by solution changes in divalent cations (Ca2+ or Mg2+). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 30 条
[1]   INVIVO ELECTROCHEMICAL MEASUREMENTS IN THE CNS [J].
ADAMS, RN .
PROGRESS IN NEUROBIOLOGY, 1990, 35 (04) :297-311
[2]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[3]  
Bunin MA, 1998, J NEUROSCI, V18, P4854
[4]   DIFFERENCES IN DOPAMINE CLEARANCE AND DIFFUSION IN RAT STRIATUM AND NUCLEUS-ACCUMBENS FOLLOWING SYSTEMIC COCAINE ADMINISTRATION [J].
CASS, WA ;
GERHARDT, GA ;
MAYFIELD, RD ;
CURELLA, P ;
ZAHNISER, NR .
JOURNAL OF NEUROCHEMISTRY, 1992, 59 (01) :259-266
[5]   CLEARANCE OF EXOGENOUS DOPAMINE IN RAT DORSAL STRIATUM AND NUCLEUS-ACCUMBENS - ROLE OF METABOLISM AND EFFECTS OF LOCALLY APPLIED UPTAKE INHIBITORS [J].
CASS, WA ;
ZAHNISER, NR ;
FLACH, KA ;
GERHARDT, GA .
JOURNAL OF NEUROCHEMISTRY, 1993, 61 (06) :2269-2278
[6]  
Chen BT, 1999, ELECTROANAL, V11, P344, DOI 10.1002/(SICI)1521-4109(199905)11:5<344::AID-ELAN344>3.3.CO
[7]  
2-B
[8]   Heterogeneity of electrically evoked dopamine release and reuptake in substantia nigra, ventral tegmental area, and striatum [J].
Cragg, SJ ;
Rice, ME ;
Greenfield, SA .
JOURNAL OF NEUROPHYSIOLOGY, 1997, 77 (02) :863-873
[9]   Effect of cocaine, nomifensine, GBR 12909 and WIN 35428 on carbon fiber microelectrode sensitivity for voltammetric recording of dopamine [J].
Davidson, C ;
Ellinwood, EH ;
Douglas, SB ;
Lee, TH .
JOURNAL OF NEUROSCIENCE METHODS, 2000, 101 (01) :75-83
[10]   In vivo chronoamperometric measurements of the clearance of exogenously applied serotonin in the rat dentate gyrus [J].
Daws, LC ;
Toney, GM ;
Davis, DJ ;
Gerhardt, GA ;
Frazer, A .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 78 (1-2) :139-150