Orthogonal signal correction in near infrared calibration

被引:56
作者
Blanco, M [1 ]
Coello, J [1 ]
Montoliu, I [1 ]
Romero, MA [1 ]
机构
[1] Univ Autonoma Barcelona, Fac Ciencias, Dept Quim, Unitat Quim Analit, E-08193 Bellaterra, Spain
关键词
orthogonal signal correction; near infrared spectroscopy; pharmaceutical analysis; data pretreatment;
D O I
10.1016/S0003-2670(01)00820-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The different physical characteristics and treatments of the solid samples are responsible for the spectral variability that takes place in near infrared (NIR) measures. These changes, not related to the analyte concentration, may yield in complex and not very robust calibration models. Mathematical treatments are usually applied for the correction of this variability being the most common derivation, standard normal variate (SNV) and multiplicative scatter correction (MSC). Orthogonal signal correction (OSC) is a new mathematical treatment designed to minimize, in a set of spectral data, the variability not related with the concentration of the analyte. In this work the application of this new treatment to minimize the spectral differences of two types of samples: production samples and laboratory samples, is evaluated. A method is developed for the determination of the content of the active component in a pharmaceutical preparation by means of PLS calibration. Results obtained by OSC are compared with those obtained with the original data and with those corrected by derivation, SNV and MSG. OSC treatment leads to PLS calibration models with good prediction ability and simpler than those obtained using other pretreatments. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 11 条
[1]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[2]   Near-infrared analytical control of pharmaceuticals. A single calibration model from mixed phase to coated tablets [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Serrano, D .
ANALYST, 1998, 123 (11) :2307-2312
[3]   Near-infrared spectroscopy in the pharmaceutical industry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
de la Pezuela, C .
ANALYST, 1998, 123 (08) :135R-150R
[4]   Strategies for constructing the calibration set in the determination of active principles in pharmaceuticals by near infrared diffuse reflectance spectrometry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
delaPezuela, C .
ANALYST, 1997, 122 (08) :761-765
[5]  
Dhanoa M., 1994, Journal of Near Infrared Spectroscopy, V2, P43, DOI [10.1255/jnirs.30, DOI 10.1255/JNIRS.30]
[6]   LINEARIZATION AND SCATTER-CORRECTION FOR NEAR-INFRARED REFLECTANCE SPECTRA OF MEAT [J].
GELADI, P ;
MACDOUGALL, D ;
MARTENS, H .
APPLIED SPECTROSCOPY, 1985, 39 (03) :491-500
[7]  
McClure W.F., 1993, NIR NEWS, V4, P12, DOI DOI 10.1255/NIRN.220
[8]  
McClure W.F., 1994, NIR NEWS, V5, P12
[9]   SPECTROPHOTOMETRIC MULTICOMPONENT ANALYSIS APPLIED TO TRACE-METAL DETERMINATIONS [J].
OTTO, M ;
WEGSCHEIDER, W .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :63-69
[10]   An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra [J].
Sjöblom, J ;
Svensson, O ;
Josefson, M ;
Kullberg, H ;
Wold, S .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 44 (1-2) :229-244