Quantitative analysis of bacterial and mammalian proteomes using a combination of cysteine affinity tags and 15N-Metabolic labeling

被引:224
作者
Conrads, TP
Alving, K
Veenstra, TD
Belov, ME
Anderson, GA
Anderson, DJ
Lipton, MS
Pasa-Tolic, L
Udseth, HR
Chrisler, WB
Thrall, BD
Smith, RD
机构
[1] Pacific NW Natl Lab, Mol Biosci Dept, Richland, WA 99352 USA
[2] Pacific NW Natl Lab, Environm & Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac001487x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the combined use of N-15-metabolic labeling and a cysteine-reactive biotin affinity tag to isolate and quantitate cysteine-containing polypeptides (Cys-polypeptides) from Deinococcus radiodurans as well as from mouse B16 melanoma cells. D, radiodurans were cultured in both natural isotopic abundance and N-15-enriched media. Equal numbers of cells from both cultures were combined and the soluble proteins extracted, This mixture of isotopically distinct proteins was derivatized using a commercially available cysteine-reactive reagent that contains a biotin group. Following trypsin digestion, the resulting modified peptides were isolated using immobilized avidin. The mixture was analyzed by capillary reversed-phase liquid chromatography (LC) on-line with ion trap mass spectrometry (RIS) as well as Fourier transform ion cyclotron resonance (FTICR) MS. The resulting spectra contain numerous pairs of Cys-polypeptides whose mass difference corresponds to the number of nitrogen atoms present in each of the peptides. Designation of Cys-polypeptide pairs is also facilitated by the distinctive isotopic distribution of the N-15-labeled peptides versus their N-14-labeled counterparts, Studies with mouse B16 cells maintained in culture allowed the observation of hundreds of isotopically distinct pairs of peptides by LC-FTICR analysis. The ratios of the areas of the pairs of isotopically distinct peptides showed the expected 1:I labeling of the N-14 arid N-15 versions of each peptide. An additional benefit from the present strategy Is that the N-15-labeled peptides do not display significant isotope-dependent chromatographic shifts from their N-14-labeled counterparts, therefore improving the precision for quantitating peptide abundances. The methodology presented offers an alternate, cost-effective strategy for conducting global, quantitative proteomic measurements.
引用
收藏
页码:2132 / 2139
页数:8
相关论文
共 33 条
  • [1] ALVING K, UNPUB
  • [2] Belov ME, 2000, J AM SOC MASS SPECTR, V11, P19, DOI 10.1016/S1044-0305(99)00121-X
  • [3] Zeptomole-sensitivity electrospray ionization - Fourier transform ion cyclotron resonance mass spectrometry of proteins
    Belov, ME
    Gorshkov, MV
    Udseth, HR
    Anderson, GA
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (10) : 2271 - 2279
  • [4] Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Auberry, KJ
    Harkewicz, R
    Smith, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) : 38 - 48
  • [5] Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Udseth, HR
    Conrads, TP
    Veenstra, TD
    Masselon, CD
    Gorshkov, MV
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 253 - 261
  • [6] BELOV ME, UNPUB INT J MASS SPE
  • [7] Campbell JM, 1998, RAPID COMMUN MASS SP, V12, P1463, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1463::AID-RCM357>3.3.CO
  • [8] 2-8
  • [9] 2D protein electrophoresis: can it be perfected?
    Celis, JE
    Gromov, P
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1999, 10 (01) : 16 - 21
  • [10] Utility of accurate mass tags for proteome-wide protein identification
    Conrads, TP
    Anderson, GA
    Veenstra, TD
    Pasa-Tolic, L
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3349 - 3354