Prenatal diagnosis of mosaic trisomy 8 in a fetus with normal nuchal translucency thickness and reversed end-diastolic ductus venosus flow

被引:16
作者
Campbell, S
Mavrides, E
Prefumo, F
Presti, F
Carvalho, JS
机构
[1] Univ London St Georges Hosp, Sch Med, Dept Obstet & Gynaecol, Fetal Med Unit, London SW17 0QT, England
[2] Royal Brompton Hosp, Brompton Fetal Cardiol, London SW3 6LY, England
关键词
trisomy; 8; prenatal diagnosis; ductus venosus; nuchal translucency;
D O I
10.1046/j.1469-0705.2001.00393.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We report a case of the prenatal diagnosis of trisomy 8 in a fetus presenting with normal nuchal translucency of 0.8 mm and reversed end-diastolic ductus venosus blood flow at a routine first-trimester scan at 11 weeks of gestation. No structural abnormalities were detected by the ultrasound scan. Karyotyping by chorionic villus sampling led to the diagnosis of mosaic trisomy 8, which was confirmed by fluorescent in-situ hybridization on fetal tissue samples.
引用
收藏
页码:341 / 343
页数:3
相关论文
共 22 条
[1]  
BERRY AC, 1978, CLIN GENET, V14, P105
[2]   Abnormal ductus venosus blood flow in trisomy 21 fetuses during early pregnancy [J].
Borrell, A ;
Antolin, E ;
Costa, D ;
Farre, MT ;
Martinez, JM ;
Fortuny, A .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (06) :1612-1617
[3]   A 3-YEAR FOLLOW-UP ON A CHILD WITH LOW-LEVEL TRISOMY-8 MOSAICISM WHICH WAS DIAGNOSED PRENATALLY [J].
CAMURRI, L ;
CHIESI, A .
PRENATAL DIAGNOSIS, 1991, 11 (01) :59-62
[4]   PRENATAL-DIAGNOSIS OF TRISOMY-8 MOSAICISM IN CVS AFTER ABNORMAL ULTRASOUND FINDINGS AT 12 WEEKS [J].
GUICHET, A ;
BRIAULT, S ;
TOUTAIN, A ;
PAILLET, C ;
DESCAMPS, P ;
PIERRE, F ;
BODY, G ;
MORAINE, CL .
PRENATAL DIAGNOSIS, 1995, 15 (08) :769-772
[5]   FETAL VENOUS, INTRACARDIAC, AND ARTERIAL BLOOD-FLOW MEASUREMENTS IN INTRAUTERINE GROWTH-RETARDATION - RELATIONSHIP WITH FETAL BLOOD-GASES [J].
HECHER, K ;
SNIJDERS, R ;
CAMPBELL, S ;
NICOLAIDES, K .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 173 (01) :10-15
[6]   ASSESSMENT OF FETAL COMPROMISE BY DOPPLER ULTRASOUND INVESTIGATION OF THE FETAL CIRCULATION - ARTERIAL, INTRACARDIAC, AND VENOUS-BLOOD FLOW VELOCITY STUDIES [J].
HECHER, K ;
CAMPBELL, S ;
DOYLE, P ;
HARRINGTON, K ;
NICOLAIDES, K .
CIRCULATION, 1995, 91 (01) :129-138
[7]   Transient increase in nuchal translucency thickness and reversed end diastolic ductus venosus flow in a fetus with trisomy 18 [J].
Huisman, TWA ;
Bilardo, CM .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 10 (06) :397-399
[8]   Using fetal nuchal translucency to screen for major congenital cardiac defects at 10-14 weeks of gestation: population based cohort study [J].
Hyett, J ;
Perdu, M ;
Sharland, G ;
Snijders, R ;
Nicolaides, KH .
BRITISH MEDICAL JOURNAL, 1999, 318 (7176) :81-85
[9]   Abnormalities of the heart and great arteries in chromosomally normal fetuses with increased nuchal translucency thickness at 11-13 weeks of gestation [J].
Hyett, J ;
Moscoso, G ;
Papapanagiotou, G ;
Perdu, M ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1996, 7 (04) :245-250
[10]  
Hyett J, 1997, AM J MED GENET, V69, P207, DOI 10.1002/(SICI)1096-8628(19970317)69:2<207::AID-AJMG18>3.0.CO