Increased sensitivity in thick-target particle induced X-ray emission analyses using dry ashing for preconcentration

被引:15
作者
Lill, JO
Harju, L [1 ]
Saarela, KE
Lindroos, A
Heselius, SJ
机构
[1] Abo Akad Univ, Analyt Chem Lab, FIN-20500 Turku, Finland
[2] Abo Akad Univ, Dept Geol & Mineral, FIN-20500 Turku, Finland
[3] Abo Akad Univ, Turku PET Ctr, Accelerator Lab, FIN-20500 Turku, Finland
[4] Abo Akad Univ, Dept Phys, FIN-20500 Turku, Finland
关键词
PIXE; dry ashing; preconcentration; limits of detection; plant materials;
D O I
10.1016/S0003-2670(98)00630-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitivity in thick-target particle induced X-ray emission (PIXE) analyses of biological materials can be enhanced by dry ashing, The gain depends mainly on the mass reduction factor and the composition of the residual ash, The enhancement factor was 7 for the certified reference material Pine Needles and the limits of detection (LODs) were below 0.2 mu g/g for Zn, Cu, Rb and Sr. When ashing biological materials with low ash contents such as wood of pine or spruce (0.3% of dry weight) and honey (0.1% of wet weight) the gain was far greater. The LODs for these materials were 30 ng/g for wood and below 10 ng/g for honey. In addition, the ashed samples were more homogenous and more resistant to changes during the irradiation than the original biological samples. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 19 条
[1]   MICROSAMPO - PERSONAL-COMPUTER BASED ADVANCED GAMMA-SPECTRUM ANALYSIS SYSTEM [J].
AARNIO, PA ;
ROUTTI, JT ;
SANDBERG, JV .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1988, 124 (02) :457-466
[2]   PIXE-ANALYSIS WITH 6-MEV H-2(+)-IONS [J].
DAHLBACKA, J ;
LINDBLOM, P .
PHYSICA SCRIPTA, 1979, 20 (5-6) :655-656
[3]   TRACE-ELEMENT ANALYSIS OF MATERNAL SCALP HAIR BY EXTERNAL BEAM PROTON-INDUCED X-RAY-EMISSION (PIXE) [J].
HALL, GS ;
ROACH, N ;
SIMMONS, U ;
CONG, H ;
LEE, ML ;
CUMMINGS, E .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1984, 82 (02) :329-339
[4]   Study of seasonal variations of trace-element concentrations within tree rings by thick-target PIXE analyses [J].
Harju, L ;
Lill, JO ;
Saarela, KE ;
Heselius, SJ ;
Hernberg, FJ ;
Lindroos, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 :536-541
[5]   Analysis of trace elements in trunk wood by thick-target PIXE using dry ashing for preconcentration [J].
Harju, L ;
Lill, JO ;
Saarela, KE ;
Heselius, SJ ;
Hernberg, FJ ;
Lindroos, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (04) :523-528
[6]  
HERNBERG FJ, 1997, THESIS ABO AKAD U TU
[7]  
Johansson S.A.E., 1988, PIXE NOVEL TECHNIQUE
[8]  
JOHANSSON SAE, 1995, SERIES MONOGRAPHS AN, V133
[9]   X-RAY ANALYSIS - ELEMENTAL TRACE ANALYSIS AT 10-12G LEVEL [J].
JOHANSSON, TB ;
AKSELSSON, R ;
JOHANSSON, SA .
NUCLEAR INSTRUMENTS & METHODS, 1970, 84 (01) :141-+
[10]   A NOVEL METHOD FOR CHARGE INTEGRATION IN EXTERNAL-BEAM TTPIXE - APPLICATION TO ANALYSES OF BIOLOGICAL-MATERIALS [J].
LILL, JO ;
SAARELA, KE ;
HERNBERG, FJ ;
HESELIUS, SJ ;
HARJU, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 83 (03) :387-393