Quantification of Perfusion and Permeability in Multiple Sclerosis Dynamic Contrast-Enhanced MRI in 3D at 3T

被引:85
作者
Ingrisch, Michael [1 ]
Sourbron, Steven [2 ]
Morhard, Dominik
Ertl-Wagner, Birgit
Kuempfel, Tania [3 ]
Hohlfeld, Reinhard [3 ]
Reiser, Maximilian
Glaser, Christian
机构
[1] Univ Munich, Munich Univ Hosp Grosshadern, Inst Clin Radiol, Josef Lissner Lab Biomed Imaging,Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Leeds, Div Med Phys, Leeds, W Yorkshire, England
[3] Univ Munich, Univ Hosp Munich Grosshadern, Inst Klin Neuroimmunol, D-81377 Munich, Germany
关键词
dynamic contrast-enhanced MRI; 3D; multiple sclerosis; quantification of perfusion; CONTRAST-ENHANCED MRI; BRAIN-BARRIER PERMEABILITY; T-1-WEIGHTED MRI; GADOLINIUM-DTPA; PHARMACOKINETIC ANALYSIS; HEMODYNAMIC IMPAIRMENT; BOLUS-TRACKING; BLOOD-VOLUME; LESIONS; TRACER;
D O I
10.1097/RLI.0b013e31823bfc97
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and Purpose: The quantification of cerebral blood flow (CBF), cerebral blood volume (CBV), and blood-brain barrier permeability in scattered lesions in the brain is a methodological challenge. We aimed to investigate the feasibility of a 3D T1-weighted dynamic contrast-enhanced (DCE) MRI acquisition in combination with a 2-compartment modeling approach for the quantification of CBF, CBV and permeability surface area product (PS) in lesions, and normal-appearing white matter (NAWM) in patients with multiple sclerosis (MS). Material and Methods: In all, 19 MS patients (mean age 35 years, 12 female) underwent DCE-MRI with a 3D T1-weighted spoiled gradient-echo sequence on a 3T MRI scanner. A total of 44 slices (thickness 3 mm) with an in-plane resolution of 1.7 x 1.7 mm(2) (matrix size 128 x 104), providing coverage of the whole brain, were acquired every 2.1 seconds over a total measurement time of 420 s. Data postprocessing was performed using a set of 2-compartment models with automated model selection; CBF, CBV, and PS as a measure of blood-brain barrier leakage were determined in contrast-enhancing (CE) and nonenhancing lesions as well as in NAWM. Results: Perfusion quantification produced reasonable values in lesions as well as in NAWM. In CE lesions, CBF (22.9 (22.7) vs. 15.8 (6.7) mL/100 mL/min), CBV (1.18 (0.48) vs. 0.76 (0.19) mL/100 mL), and PS (0.98 (0.46) vs. 0.04 (0.03) mL/100 mL/min) were significantly (P < 0.001) higher than in NAWM. In nonenhancing lesions, a weakly (P < 0.05) significantly increased CBV of 1.00 (0.35) mL/100 mL, compared with NAWM, was observed. Conclusion: Our study demonstrates the feasibility of 3D T1-weighted DCE-MRI for the quantitative assessment of CBF, CBV, and PS in NAWM as well as in multiple MS lesions scattered throughout the brain, even without previous knowledge of their location. Quantification on the region level produced reasonable values both in lesions and in NAWM, but parameter maps would benefit from an increase in contrast-to-noise ratio. The increased values of CBF, CBV, and PS in CE lesions may reflect inflammatory activity, the heterogeneity of parameter estimates suggests a potential for lesion characterization. NAWM appears hypoperfused, this is in accordance with previous studies, but requires validation with a control group.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 38 条
[1]   Pattern of hemodynamic impairment in multiple sclerosis: Dynamic susceptibility contrast perfusion MR imaging at 3.0 T [J].
Adhya, Sumita ;
Johnson, Glyn ;
Herbert, Joseph ;
Jaggi, Hina ;
Babb, James S. ;
Grossman, Robert I. ;
Inglese, Matilde .
NEUROIMAGE, 2006, 33 (04) :1029-1035
[2]   Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series [J].
Brix, G ;
Kiessling, F ;
Lucht, R ;
Darai, S ;
Wasser, K ;
Delorme, S ;
Griebel, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :420-429
[3]   Tracer kinetic modelling of tumour angiogenesis based on dynamic contrast-enhanced CT and MRI measurements [J].
Brix, Gunnar ;
Griebel, Juergen ;
Kiessling, Fabian ;
Wenz, Frederik .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 :S30-S51
[4]   Pharmacokinetic analysis of tissue microcirculation using nested models: Multimodel inference and parameter identifiability [J].
Brix, Gunnar ;
Zwick, Stefan ;
Kiessling, Fabian ;
Griebel, Juergen .
MEDICAL PHYSICS, 2009, 36 (07) :2923-2933
[5]   Comprehensive model for simultaneous MRI determination of perfusion and permeability using a blood-pool agent in rats rhabdomyosarcoma [J].
de Bazelaire, C ;
Siauve, N ;
Fournier, L ;
Frouin, F ;
Robert, P ;
Clement, O ;
de Kerviler, E ;
Cuenod, CA .
EUROPEAN RADIOLOGY, 2005, 15 (12) :2497-2505
[6]   A Comparison of Tracer Kinetic Models for T1-Weighted Dynamic Contrast-Enhanced MRI: Application in Carcinoma of the Cervix [J].
Donaldson, Stephanie B. ;
West, Catharine M. L. ;
Davidson, Susan E. ;
Carrington, Bernadette M. ;
Hutchison, Gillian ;
Jones, Andrew P. ;
Sourbron, Steven P. ;
Buckley, David L. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :691-700
[7]   Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS [J].
Filippi, M ;
Yousry, T ;
Campi, A ;
Kandziora, C ;
Colombo, B ;
Voltz, R ;
Martinelli, V ;
Spuler, S ;
Bressi, S ;
Scotti, G ;
Comi, G .
NEUROLOGY, 1996, 46 (02) :379-384
[8]  
Ge Y, 2006, AM J NEURORADIOL, V27, P1165
[9]  
Ge YL, 2005, AM J NEURORADIOL, V26, P1539
[10]   Choosing the optimal fit function: Comparison of the Akaike information criterion and the F-test [J].
Glatting, Gerhard ;
Kletting, Peter ;
Reske, Sven N. ;
Hohl, Kathrin ;
Ring, Christina .
MEDICAL PHYSICS, 2007, 34 (11) :4285-4292