Does the type of prosthesis influence the incidence of permanent pacemaker implantation following isolated aortic valve replacement

被引:9
作者
Elahi, MM [1 ]
Osman, KA
Bhandari, M
Dhannapuneni, RRV
机构
[1] Glenfield Gen Hosp, Dept Cardiothorac Surg, Leicester LE3 9QP, Leics, England
[2] Glenfield Gen Hosp, Dept Cardiol, Leicester LE3 9QP, Leics, England
关键词
D O I
10.1532/HSF98.20051025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The incidence of conduction disorders requiring permanent pacing (PPM) in patients operated on for aortic valve replacement (AVR) has been reported to be 5.7%. However, perioperative risk predictors for PPM following AVR are not well characterized and debate exists regarding selection of the prosthesis-type most likely to minimize this incidence. The aim of the study was to assess whether the type of the prosthesis used influences the prevalence of PPM following aortic valve replacement. Methods: A total of 782 consecutive patients with predominant aortic stenosis accepted for isolated non-emergent AVR were studied over a 3 year period; of which 305 patients ( Group A) received mechanical prostheses, 335 received stented tissue prostheses ( Group B), and the remaining 142 received stentless tissue valves ( Group C). A stepwise logistic regression analysis was used to identify the independent predictors for PPM and statistical significance was accepted at a level of P <.05. Results: Univariate and multivariate analyses showed a significant relationship between the preoperative factors ( poor ejection fraction < 35%; P <.001), left atrial enlargement (LAE; P <.001) and left bundle branch block (LBBB; P <.001), the perioperative variables ( bypass time > 100 minutes with x-clamp time > 70 minutes; P <.001) and the incidence of PPM. Conclusions: The proposed predictive model correlated highly with actual pacemaker use, suggesting that the requirement for PPM results from either operative trauma or increased ischemic burden and the incidence of PPM is independent of prosthesis-type implanted.
引用
收藏
页码:E396 / E400
页数:5
相关论文
共 19 条
[1]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[2]  
BOUGHALEB D, 1994, ARCH MAL COEUR VAISS, V87, P925
[3]   Aortic valve replacement: an update at the turn of the millennium [J].
Braunwald, E .
EUROPEAN HEART JOURNAL, 2000, 21 (13) :1032-1033
[4]  
BREISCH EA, 1984, LAB INVEST, V51, P333
[5]   Cardiac pacing following surgery for acquired heart disease [J].
DelRizzo, DF ;
Nishimura, S ;
Lau, C ;
Sever, J ;
Goldman, BS .
JOURNAL OF CARDIAC SURGERY, 1996, 11 (05) :332-340
[6]  
ELAHI MM, 2005, IN PRESS BR J CARDIO
[7]   Effect of aortic valve replacement on C-reactive protein in nonrheumatic aortic stenosis [J].
Gerber, IL ;
Stewart, RAH ;
Hammett, CJK ;
Legget, ME ;
Oxenham, H ;
West, TM ;
French, JK ;
White, HD .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (09) :1129-1132
[8]  
GOLDMAN BS, 1994, J CARDIOVASC SURG, V35, P105
[9]   Permanent cardiac pacing after a cardiac operation: Predicting the use of permanent pacemakers [J].
Gordon, RS ;
Ivanov, J ;
Cohen, G ;
Ralph-Edwards, AL .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :1698-1704
[10]   FIBRILLAR COLLAGEN AND MYOCARDIAL STIFFNESS IN THE INTACT HYPERTROPHIED RAT LEFT-VENTRICLE [J].
JALIL, JE ;
DOERING, CW ;
JANICKI, JS ;
PICK, R ;
SHROFF, SG ;
WEBER, KT .
CIRCULATION RESEARCH, 1989, 64 (06) :1041-1050