Exergetic analysis of transcritical CO2 residential air-conditioning system based on experimental data

被引:63
作者
Tao, Y. B. [1 ]
He, Y. L. [1 ]
Tao, W. Q. [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Sch Energy & Power Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
CO2; refrigerant; Air-conditioning; Exergetic efficiency; Exergy loss; 2ND LAW ANALYSIS; HEAT-PUMP; REFRIGERATION SYSTEMS; CYCLE; PERFORMANCE;
D O I
10.1016/j.apenergy.2010.03.003
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The experimental system for the transcritical CO2 residential air-conditioning with an internal heat exchanger was built. The effects of working conditions on system performance were experimentally studied. Based on the experimental dada, the second law analysis on the transcritical CO2 system was performed. The effects of working conditions on the total exergetic efficiency of the system were investigated. The results show that in the studied parameter ranges, the exergetic efficiency of the system increases with the increases of gas cooler side air inlet temperature, gas cooler side air inlet velocity and evaporating temperature. And it will decrease with the increases of evaporator side air inlet temperature and velocity. Then, a complete exergetic analysis was performed for the entire CO2 transcritical cycle including compressor, gas cooler, expansion valve, evaporator and internal heat exchanger under different working conditions. The average exergy loss in gas cooler is the highest one under all working conditions which is about 30.7% of the total exergy loss in the system. The second is the average exergy loss in expansion valve which is about 24.9% of the total exergy loss, followed by the exergy losses in evaporator and compressor, which account for 21.9% and 19.5%, respectively. The exergy loss in internal heat exchanger is the lowest one which is only about 3.0%. So in the optimization design of the transcritical CO2 residential air-conditioning system more attentions should be paid to the gas cooler and expansion valve. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3065 / 3072
页数:8
相关论文
共 29 条
[1]  
[Anonymous], 1987, MONTREAL PROTOCOL SU
[2]   Second law analysis of thermodynamics in the electric arc furnace at a steel producing company [J].
Çamdali, Ü ;
Tunç, M ;
Karakas, A .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (06) :961-973
[3]   Parametric study and optimization of a transcritical power cycle using a low temperature source [J].
Cayer, Emmanuel ;
Galanis, Nicolas ;
Nesreddine, Hakim .
APPLIED ENERGY, 2010, 87 (04) :1349-1357
[4]   Analysis of a carbon dioxide transcritical power cycle using a low temperature source [J].
Cayer, Emmanuel ;
Galanis, Nicolas ;
Desilets, Martin ;
Nesreddine, Hakim ;
Roy, Philippe .
APPLIED ENERGY, 2009, 86 (7-8) :1055-1063
[5]   The optimum high pressure for CO2 transcritical refrigeration systems with internal heat exchangers [J].
Chen, Y ;
Gu, JJ .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1238-1249
[6]   Cooling performance of a variable speed CO2 cycle with an electronic expansion valve and internal heat exchanger [J].
Cho, Honghyun ;
Ryu, Changgi ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04) :664-671
[7]   Second law analysis of the transcritical CO2 refrigeration cycle [J].
Fartaj, A ;
Ting, DSK ;
Yang, WW .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (13-14) :2269-2281
[8]   Comparison of energy, exergy, and entropy balance methods for analysing double-stage absorption heat transformer cycles [J].
Fartaj, SA .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (14) :1219-1230
[9]   Commercial refrigeration system using CO2 as the refrigerant [J].
Girotto, S ;
Minetto, S ;
Neksa, P .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (07) :717-723
[10]  
GIROTTO S, 2002, P NEW TECHN COMM REF, P3