Near-infrared trace-gas sensors based on room-temperature diode lasers

被引:65
作者
Werle, P [1 ]
Mucke, R
D'Amato, F
Lancia, T
机构
[1] Fraunhofer Inst Atmospher Environm Res, D-82467 Garmisch Partenkirchen, Germany
[2] ENEA, Roma, Italy
[3] TRI, Scanzorosciate, BG, Italy
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 1998年 / 67卷 / 03期
关键词
D O I
10.1007/s003400050510
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Semiconductor lasers continue to find an increasing number of applications as tunable sources for high-resolution spectroscopy. Substantial improvements in sensitivity and detection speed have been achieved and many laser-based gas monitoring applications have been reported. In this paper the relevant characteristics of currently available semiconductor lasers with respect to spectroscopic gas analysis will be discussed. Experimental data from a CO2 monitor designed for field applications using room-temperature diode lasers are presented. Near-infrared DEB lasers operating at 1.57 mu m and around 2.0 mu m have been used for CO2 measurements. At ambient concentration levels a resolution of more than two orders of magnitude has been demonstrated at 1.57 mu m, at 2 mu m the precision is in the order of 0.1 ppm CO2, and for trace analysis a detection limit of 10 ppb has been obtained. The measurements demonstrate the capability of near-infrared DFB diode lasers for the precise determination of CO2 concentrations as required for climatological, medical, or industrial applications.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 27 条
[1]   FREQUENCY-MODULATION (FM) SPECTROSCOPY - THEORY OF LINESHAPES AND SIGNAL-TO-NOISE ANALYSIS [J].
BJORKLUND, GC ;
LEVENSON, MD ;
LENTH, W ;
ORTIZ, C .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1983, 32 (03) :145-152
[2]  
Brassington D.J., 1994, ADV SPECTROSCOPY, V24
[3]   Diode laser absorption measurements of CH3Cl and CH4 near 1.65 mu m [J].
Chou, SI ;
Baer, DS ;
Hanson, RK .
APPLIED OPTICS, 1997, 36 (15) :3288-3293
[4]   DOUBLE FREQUENCY-MODULATION SPECTROSCOPY - HIGH MODULATION FREQUENCY WITH LOW-BANDWIDTH DETECTORS [J].
COOPER, DE ;
GALLAGHER, TF .
APPLIED OPTICS, 1985, 24 (09) :1327-1334
[5]   MEASUREMENT OF (CO2)-C-12(CO2)-C-13 RATIOS FOR MEDICAL DIAGNOSTICS WITH 1.6-MU-M DISTRIBUTED-FEEDBACK SEMICONDUCTOR DIODE-LASERS [J].
COOPER, DE ;
MARTINELLI, RU ;
CARLISLE, CB ;
RIRIS, H ;
BOUR, DB ;
MENNA, RJ .
APPLIED OPTICS, 1993, 32 (33) :6727-6731
[6]   Very precise measurement of carbon dioxide atmospheric concentration by using TDL's [J].
DAmato, F ;
Lancia, A ;
Werle, P .
APPLICATION OF TUNABLE DIODE AND OTHER INFRARED SOURCES FOR ATMOSPHERIC STUDIES AND INDUSTRIAL PROCESS MONITORING, 1996, 2834 :242-248
[7]  
Fried A., 1996, P SPIE, V2834
[8]  
Haisch M, 1996, TECH MESS, V63, P322
[9]   COMPARISON OF EDDY-COVARIANCE MEASUREMENTS OF CO2 FLUXES BY OPEN-PATH AND CLOSED-PATH CO2 ANALYZERS [J].
LEUNING, R ;
KING, KM .
BOUNDARY-LAYER METEOROLOGY, 1992, 59 (03) :297-311
[10]   Tunable single-frequency III-V semiconductor diode lasers with wavelengths from 0.76 to 2.7 mu m [J].
Martinelli, RU ;
Menna, RJ ;
York, PK ;
Garbuzov, DZ ;
Lee, H ;
Abeles, JH ;
Morris, N ;
Connolly, JC ;
Narayan, SY ;
Vermaak, JS ;
Olsen, GH ;
Cooper, DE ;
Carlisle, CB ;
Riris, H ;
Cook, AL .
APPLICATION OF TUNABLE DIODE AND OTHER INFRARED SOURCES FOR ATMOSPHERIC STUDIES AND INDUSTRIAL PROCESS MONITORING, 1996, 2834 :2-16