Heat-pump/energy-store using silica gel and water as a working pair

被引:40
作者
Tahat, MA [1 ]
机构
[1] Jordan Univ Sci & Technol, Dept Mech Engn, Irbid, Jordan
关键词
D O I
10.1016/S0306-2619(01)00008-3
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The possibilty of using silica gel and water as a reversible pair, in a thermochemical heat-pump/energy-store has been studied theoretically and experimentally during both heating and cooling modes. With silica gel absorbing water by 25 +/-2% of the dry silica gel's weight, the heat of adsorption and the heat of wetting of 2712.43 +/- 30 kJ/kg SiO2 and 94.43 +/- 15 kJ/kg SiO2 have been achieved respectively. The concentration rate for the two reaction pair was investigated and a general relationship that governed the adsorption rate with time has been deduced. (C) 2001 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 10 条
[1]  
Alefeld G, 1978, ENERGY, V3, P649
[2]  
ANDREWS HI, 1955, MODERN REFRIGERATION, P330
[3]   PERFORMANCE LIMITATIONS OF ADSORPTION CYCLES FOR SOLAR COOLING [J].
CRITOPH, RE .
SOLAR ENERGY, 1988, 41 (01) :21-31
[4]  
Hulse G., 1929, REFRIG ENG, V17, P41
[5]  
MILLER B, 1929, DEV SILICA GEL REFRI, V17, P103
[6]  
OFFENHARTZ PO, 1980, T ASME, V102, P59
[7]  
Rogers G.F.C., 1995, THERMODYNAMIC TRANSP
[8]  
Ruthven D. M., 1984, PRINCIPLES ADSORPTIO
[9]  
TOHERNEV DI, 1979, P 14 INT EN CONV ENG, V2, P2070
[10]  
1981, Patent No. 0035871