Automated column-switching high-performance liquid chromatography for the determination of aflatoxin M1

被引:19
作者
Simon, P [1 ]
Delsaut, P [1 ]
Lafontaine, M [1 ]
Morele, Y [1 ]
Nicot, T [1 ]
机构
[1] Inst Natl Rech & Secur, F-54501 Vandoeuvre Nancy, France
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 712卷 / 1-2期
关键词
aflatoxins;
D O I
10.1016/S0378-4347(98)00139-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An extractionless method for determining aflatoxin M1 (AFM1), a major metabolite of aflatoxin B1 (AFB1), in human urine was developed. The biological fluid is injected directly into the chromatographic system after simple dilution and centrifugation. A pre-column, packed with a cation-exchange phase and coupled on-line to a column-switching liquid chromatography (LC) system, is used for sample pre-treatment and concentration. The analytes are non-selectively desorbed with the LC eluent and cleaned by means of a column-switching procedure. Pre-treatment and analysis were performed within 40 min. Average AFM1 recovery reached 97% in the 10-100 ng/l range of urine. The detection limit of AFM1 in urine and milk was 2.5 ng/l for 1 ml of injected sample. A comparison with an immunoaffinity column clean-up and LC method was performed. The method was applied to determine AFM1 in the urine of AFB1 Savaged rats, and in the urine of both potentially exposed and supposedly unexposed workers. The method was also extended to milk. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 104
页数:10
相关论文
共 20 条
[1]  
ANUKARAHANONTA T, 1983, J CHROMATOGR, V275, P383
[2]   AFLATOXIN METABOLITES IN THE URINE OF NIGERIANS COMPARISON OF CHROMATOGRAPHIC METHODS [J].
BEAN, TA ;
YOURTEE, DM ;
AKANDE, B ;
OGUNLEWE, J .
JOURNAL OF TOXICOLOGY-TOXIN REVIEWS, 1989, 8 (1-2) :43-52
[3]   DETERMINATION OF AFLATOXIN-M1 USING A DIALYSIS-BASED IMMUNOAFFINITY SAMPLE PRETREATMENT SYSTEM COUPLED ONLINE TO LIQUID-CHROMATOGRAPHY - REUSABLE IMMUNOAFFINITY COLUMNS [J].
FARJAM, A ;
VANDEMERBEL, NC ;
NIEMAN, AA ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2) :141-149
[4]   NONSELECTIVE DESORPTION OF IMMUNO PRECOLUMNS COUPLED ONLINE WITH COLUMN LIQUID-CHROMATOGRAPHY - DETERMINATION OF AFLATOXINS [J].
FARJAM, A ;
VANDEMERBEL, NC ;
LINGEMAN, H ;
FREI, RW ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1991, 45 (02) :73-87
[5]  
GROOPMAN JD, 1992, CANCER RES, V52, P267
[6]  
GROOPMAN JD, 1988, J ASSOC OFF ANA CHEM, V71, P861
[7]   A REVIEW OF MYCOTOXINS IN INDOOR AIR [J].
HENDRY, KM ;
COLE, EC .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1993, 38 (02) :183-198
[8]   IMMUNOAFFINITY COLUMN CLEANUP FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AFLATOXINS B-1, B-2, G(1), G(2), M(1) AND Q(1) IN URINE [J].
KUSSAK, A ;
ANDERSSON, B ;
ANDERSSON, K .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 672 (02) :253-259
[9]   DETERMINATION OF AFLATOXINS IN AIRBORNE DUST FROM FEED FACTORIES BY AUTOMATED IMMUNOAFFINITY COLUMN CLEANUP AND LIQUID-CHROMATOGRAPHY [J].
KUSSAK, A ;
ANDERSSON, B ;
ANDERSSON, K .
JOURNAL OF CHROMATOGRAPHY A, 1995, 708 (01) :55-60
[10]  
LAFONTAINE M, 1994, CAH NOTES DOC, V156, P297