Evaluation of dual-labeled fluorescent DNA probe purity versus performance in real-time PCR

被引:21
作者
Yeung, AT
Holloway, BP
Adams, PS
Shipley, GL
机构
[1] Fox Chase Canc Ctr, Philadelphia, PA 19111 USA
[2] Ctr Dis Control & Prevent, Atlanta, GA USA
[3] Univ Texas, Hlth Sci Ctr, Houston, TX USA
[4] Trudeau Inst, Saranac Lake, NY USA
关键词
D O I
10.2144/04362RR01
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Real-time PCR technology using dual-labeled fluorescent oligonucleotide probes allows for sensitive, specific, and quantitative determination of mRNA or DNA targets. Historically, dual-labeled probes have been the most expensive reagent in real-time PCR because of the postsynthesis high-performance liquid chromatography (HPLC) and/or gel purification steps required due to limitations in traditional synthesis chemistry. The recent availability of quencher reagents that allow the 3' quencher incorporation as part of the on-machine synthesis has presented the possibility that probes, when carefully synthesized, may be used without extensive postsynthesis purification. This would substantially reduce cost, making the synthesis of dual-labeled fluorescent probes affordable to any DNA synthesis laboratory. The Nucleic Acids Research Group (NARG) of the Association of Biomolecular Resource Facilities (ABRF) (Santa Fe, NM, USA) tested the hypothesis that now any DNA synthesis laboratory is capable of making quality dual-labeled fluorescent probes suitable for real-time PCRs without the need for postsynthesis purification. Members of the DNA synthesis community synthesized dual-labeled human beta-actin probes and submitted them for quality and functional analysis. We found that probes that were at least 20% pure had the same efficiency as those near 100% purity, but the sensitivity of the assay was reduced as the level of purity decreased.
引用
收藏
页码:266 / +
页数:7
相关论文
共 9 条
[1]   Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays [J].
Bustin, SA .
JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2000, 25 (02) :169-193
[2]   Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems [J].
Bustin, SA .
JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2002, 29 (01) :23-39
[3]   A novel method for real time quantitative RT PCR [J].
Gibson, UEM ;
Heid, CA ;
Williams, PM .
GENOME RESEARCH, 1996, 6 (10) :995-1001
[4]   Real time quantitative PCR [J].
Heid, CA ;
Stevens, J ;
Livak, KJ ;
Williams, PM .
GENOME RESEARCH, 1996, 6 (10) :986-994
[5]  
LAKOWICZ JR, 1983, PRINCIPLES FLUORESCE, P303
[6]   STRUCTURE-SPECIFIC ENDONUCLEOLYTIC CLEAVAGE OF NUCLEIC-ACIDS BY EUBACTERIAL DNA-POLYMERASES [J].
LYAMICHEV, V ;
BROW, MAD ;
DAHLBERG, JE .
SCIENCE, 1993, 260 (5109) :778-783
[7]   Real-time PCR in virology [J].
Mackay, IM ;
Arden, KE ;
Nitsche, A .
NUCLEIC ACIDS RESEARCH, 2002, 30 (06) :1292-1305
[8]  
Zhu YF, 1996, RAPID COMMUN MASS SP, V10, P383, DOI 10.1002/(SICI)1097-0231(199602)10:3<383::AID-RCM485>3.3.CO
[9]  
2-N