Radiopaque polymeric materials for medical applications -: Current aspects of biomaterial research

被引:49
作者
Mottu, F
Rüfenacht, DA
Doelker, E
机构
[1] Univ Geneva, Sch Pharm, Dept Pharmaceut Technol, CH-1211 Geneva 4, Switzerland
[2] Univ Geneva, Div Diagnost & Intervent Radiol, Geneva, Switzerland
关键词
biomaterials; radiopacity; x-ray imaging; radiopaque polymers; polymers; implants; inserts; review;
D O I
10.1097/00004424-199905000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this review is to give an overview and some insight into different radiopaque polymeric materials that are currently used as medical implants or inserts. The advantages and limitations of each radiopaque polymeric material are summarized. The main method used to make medical implants radiologically visible is based on blending polymers with conventional radiopaque agents, blends which usually are a physical mixture of acrylic derivatives and inorganic salts, Other methods reported involve either the formation of single-phase radiopaque polymer salt complexes somehow preventing the release of the radiopacifying element by entrapment of the complex in a crosslinked network, or radiopaque polymerized monomers characterized by a radiopacifying element associated with the monomer unit prior to polymerization, In the near future, research will certainly concentrate on biocompatible radiopaque polymers,vith covalently bound opaque elements leading to stable polymers with properties equivalent to the nonopaque, parent polymer.
引用
收藏
页码:323 / 335
页数:13
相关论文
共 139 条
[1]   RADIOPACITY OF COMPOSITE RESTORATIVE MATERIALS [J].
ABOUTABL, ZM ;
TIDY, DC ;
COMBE, EC .
BRITISH DENTAL JOURNAL, 1979, 147 (07) :187-188
[2]  
ACKERMAN JR, 1982, ENCY CHEM TECHNOLOGY, P786
[3]  
AKIMOVA AY, 1988, Patent No. 2610828
[4]   RADIOPACITY OF ACRYLIC RESINS [J].
ALVARES, LC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1966, 22 (03) :318-&
[5]   TREATMENT OF INTRA-CEREBRAL ARTERIOVENOUS-MALFORMATIONS WITH ISOBUTYL 2-CYANOACRYLATE - INITIAL CLINICAL-EXPERIENCE [J].
BANK, WO ;
KERBER, CW ;
CROMWELL, LD .
RADIOLOGY, 1981, 139 (03) :609-616
[6]   STUDIES ON A NEW RADIOPAQUE POLYMERIC BIOMATERIAL [J].
BENZINA, A ;
KRUFT, MAB ;
BAR, F ;
VANDERVEEN, FH ;
BASTIAANSEN, CW ;
HEIJNEN, V ;
REUTELINGSPERGER, C ;
KOOLE, LH .
BIOMATERIALS, 1994, 15 (14) :1122-1128
[7]  
Benzina A, 1996, J BIOMED MATER RES, V32, P459, DOI 10.1002/(SICI)1097-4636(199611)32:3<459::AID-JBM20>3.0.CO
[8]  
2-A
[9]   CATHETER AND MATERIAL SELECTION FOR TRANS-ARTERIAL EMBOLIZATION - TECHNICAL CONSIDERATIONS .2. MATERIALS [J].
BERENSTEIN, A ;
KRICHEFF, II .
RADIOLOGY, 1979, 132 (03) :631-639
[10]  
BOENIG HV, 1973, STRUCTURE PROPERTIES