The CFTA evaluation of alternatives program: An evaluation of in vitro alternatives to the Draize primary eye irritation test. (Phase III) surfactant-based formulations

被引:65
作者
Gettings, SD
Lordo, RA
Hintze, KL
Bagley, DM
Casterton, PL
Chudkowski, M
Curren, RD
Demetrulias, JL
Dipasquale, LC
Earl, LK
Feder, PI
Galli, CL
Glaza, SM
Gordon, VC
Janus, J
Kurtz, PJ
Marenus, KD
Moral, J
Pape, WJW
Renskers, KJ
Rheins, LA
Roddy, MT
Rozen, MG
Tedeschi, JP
Zyracki, J
机构
[1] BATTELLE MEM INST, COLUMBUS, OH 43210 USA
[2] PROCTER & GAMBLE CO, CINCINNATI, OH 45241 USA
[3] COLGATE PALMOLIVE CO, PISCATAWAY, NJ 08855 USA
[4] AMWAY CORP, ADA, MI 49355 USA
[5] JOHNSON & JOHNSON CONSUMER PROD INC, SKILLMAN, NJ 08558 USA
[6] MICROBIOL ASSOCIATES INC, ROCKVILLE, MD 20850 USA
[7] DIAL CORP, SCOTTSDALE, AZ 85254 USA
[8] GILLETTE MED EVALUAT LABS, GAITHERSBURG, MD 20879 USA
[9] UNIPRO, RES CTR COSMET TOXICOL, MILAN, ITALY
[10] HAZLETON WISCONSIN INC, MADISON, WI 53704 USA
[11] INVITRO INT, IRVINE, CA 92714 USA
[12] CLONET CORP, SAN DIEGO, CA 92123 USA
[13] ESTEE LAUDER INC, MELVILLE, NY 11747 USA
[14] REVLON INC, EDISON, NJ 08818 USA
[15] BEIERSDORF AG, HAMBURG 20, GERMANY
[16] AVON PROD INC, SUFFERN, NY 10901 USA
[17] ADV TISSUE SCI INC, LA JOLLA, CA 92037 USA
[18] PROCTER & GAMBLE CO, HUNT VALLEY, MD 21030 USA
[19] MARY KAY COSMET INC, DALLAS, TX 75247 USA
[20] LOREAL, CLARK, NJ 07066 USA
[21] BRISTOL MYERS SQUIBB, HILLSIDE, NJ 07205 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1016/0278-6915(96)89525-1
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The CTFA Evaluation of Alternatives Program is an evaluation of the relationship between data from the Draize primary eye irritation test and comparable data from a selection of promising in vitro eye irritation tests. In Phase III,data from the Draize test and 41 in vitro endpoints on 25 representative surfactant-based personal care formulations were compared. As in Phase I and Phase II, regression modelling of the relationship between maximum average Draize score (MAS) and in vitro endpoint was the primary approach adopted for evaluating in vitro assay performance. The degree of confidence in prediction of MAS for a given in vitro endpoint is quantified in terms of the relative widths of prediction intervals constructed about the fitted regression curve. Prediction intervals reflect not only the error attributed to the model but also the material-specific components of variation in both the Draize and the in vitro assays. Among the in vitro assays selected for regression modelling in Phase III, the relationship between MAS and in vitro score was relatively well defined. The prediction bounds on MAS were most narrow for materials at the lower or upper end of the effective irritation range (MAS = 0-45), where variability in MAS was smallest. Thus, the confidence with which the MAS of surfactant-based formulations is predicted is greatest when MAS approaches zero or when MAS approaches 45 (no comment is made on prediction of MAS > 45 since extrapolation beyond the range of observed data is not possible). No single in vitro endpoint was found to exhibit relative superiority with regard to prediction of MAS. Variability associated with Draize test outcome (e.g. in MAS values) must be considered in any future comparisons of in vivo and in vitro test results if the purpose is to predict in vivo response using in vitro data.
引用
收藏
页码:79 / 117
页数:39
相关论文
共 60 条
[1]  
[Anonymous], 1982, The Jackknife, the Bootstrap and Other Resampling Plans
[2]  
BABICH H, 1989, ALTERN METH, V7, P153
[3]  
BAGLEY DM, 1991, J TOXICOL-CUTAN OCUL, V10, P95
[4]  
BAGLEY DM, 1991, J TOXICOL-CUTAN OCUL, V10, P105
[5]  
BELL E, 1989, PHARM APPLICATIONS C, P131
[6]   COMPARISONS OF 2-INVITRO CYTO-TOXICITY ASSAYS - THE NEUTRAL RED (NR) AND TETRAZOLIUM MTT TESTS [J].
BORENFREUND, E ;
BABICH, H ;
MARTINALGUACIL, N .
TOXICOLOGY IN VITRO, 1988, 2 (01) :1-6
[7]   TOXICITY DETERMINED INVITRO BY MORPHOLOGICAL ALTERATIONS AND NEUTRAL RED ABSORPTION [J].
BORENFREUND, E ;
PUERNER, JA .
TOXICOLOGY LETTERS, 1985, 24 (2-3) :119-124
[8]   EVALUATION OF 7 INVITRO ALTERNATIVES FOR OCULAR SAFETY TESTING [J].
BRUNER, LH ;
KAIN, DJ ;
ROBERTS, DA ;
PARKER, RD .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1991, 17 (01) :136-149
[9]  
Bulich, 1986, TOXICITY TESTING USI, V1, P57
[10]   THE INVITRO ASSESSMENT OF SEVERE EYE IRRITANTS [J].
BURTON, ABG ;
YORK, M ;
LAWRENCE, RS .
FOOD AND COSMETICS TOXICOLOGY, 1981, 19 (04) :471-480