Investigating the knot performance of silk, polyamide, polyester, and polypropylene sutures

被引:30
作者
Bayraktar, EK [1 ]
Hockenberger, AS [1 ]
机构
[1] Uludag Univ, Dept Text Engn, TR-16059 Gorukle, Bursa, Turkey
关键词
D O I
10.1177/004051750107100511
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
The knot performance of four different nonabsorbable sutures-silk, polyester, polyamide, and polypropylene-is investigated by using square knots with two and three throws. All sutures are USP 2/0 in size. An instrument that can be mounted on the Instron tensile tester measures the knot performance of the sutures. The results are given as stress-elongation graphic, knot slippage, and knot break values. The effects of the number of throws and the structure of the sutures on knot performance are studied. For the knot performance tests, the effect of the physical structure (braided or monofilament) is clearly seen. For monofilament polyamide and polypropylene sutures, the knot with two throws unties before it breaks. For silk and polyester braided sutures, which have reasonably good two-throw square knot strength, the added throw does not remarkably increase strength and at the same time places more suture material in the tissue, which increases the risk of infection. Three-throw knot results reveal that the suture material plays an important role in knot strength.
引用
收藏
页码:435 / 440
页数:6
相关论文
共 11 条
[1]  
BAYRAKTAR EK, 1999, THESIS U ULUDAG TURK
[2]  
CHU CC, 1997, WOUND CLOSURE BIOMAT, P123
[3]   MECHANICAL COMPARISON OF 10 SUTURE MATERIALS BEFORE AND AFTER IN-VIVO INCUBATION [J].
GREENWALD, D ;
SHUMWAY, S ;
ALBEAR, P ;
GOTTLIEB, L .
JOURNAL OF SURGICAL RESEARCH, 1994, 56 (04) :372-377
[4]  
Herrmann J B, 1971, Am Surg, V37, P209
[5]  
MUKHERJEE DP, 1987, ENCY POLYM SCI ENG, V16, P473
[6]  
PLANCK H, 1989, P 3 INT ITV C BIOM S, P231
[7]  
RODEHEAVER GT, 1981, SURG GYNECOL OBSTET, V153, P835
[8]   MECHANICAL PERFORMANCE OF SUTURES IN SURGERY [J].
THACKER, JG ;
RODEHEAVER, G ;
KURTZ, L ;
EDGERTON, MT ;
EDLICH, RF .
AMERICAN JOURNAL OF SURGERY, 1977, 133 (06) :713-715
[9]   MECHANICAL PERFORMANCE OF SURGICAL SUTURES [J].
THACKER, JG ;
RODEHEAVER, G ;
MOORE, JW ;
KAUZLARICH, JJ ;
KURTZ, L ;
EDGERTON, MT ;
EDLICH, RF .
AMERICAN JOURNAL OF SURGERY, 1975, 130 (03) :374-380
[10]   HANDLING CHARACTERISTICS OF BRAIDED SUTURE MATERIALS FOR TIGHT TYING [J].
TOMITA, N ;
TAMAI, S ;
MORIHARA, T ;
IKEUCHI, K ;
IKADA, Y .
JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (01) :61-65