Rotating disk electrode voltammetric measurements of dopamine transporter activity: An analytical evaluation

被引:34
作者
Earles, C
Schenk, JO [1 ]
机构
[1] Washington State Univ, Dept Chem, Pullman, WA 99164 USA
[2] Washington State Univ, Dept Biochem & Biophys, Pullman, WA 99164 USA
[3] Washington State Univ, Programs Pharmacol Toxicol, Pullman, WA 99164 USA
[4] Washington State Univ, Program Neurosci, Pullman, WA 99164 USA
关键词
D O I
10.1006/abio.1998.2850
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rotating disk electrode (RDE) voltammetry at glassy carbon electrodes in 300- to 500-mu L volumes has been shown in the literature by this laboratory and others to be useful in measuring dopamine and norepinephrine inward transport and release in preparations from rat brain and in expression systems. However, an analytical evaluation of the technique has not been made, and it is presented here in studies in striatal suspensions and human embryonic kidney cells expressing the human transporter for dopamine. The RDE was found to be able to measure dopamine and its metabolites with linear responses over the range of physiologically relevant concentrations with practical limits of quantification in the 10 to 50 nM range without signal and/or signal to noise enhancements. Response times of the technique were found to vary between 20 and 60 ms depending on rotation rate. Release and inward transport velocities were shown to be kinetically resolved. The glassy carbon electrode was found to be useful for several years at physiological temperatures without significant changes in electrochemical surface area, residual current, or response factors. Some sources of error in the measurement of release and inward transport values of velocity were noted and described. (C) 1998 Academic Press.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 31 条
  • [1] Adams R.N., 1969, Electrochemistry at Solid Electrodes
  • [2] BARD AJ, 1980, ELECTROCHEMICAL METH, P280
  • [3] SMALL-VOLUME ELECTROCHEMICAL-CELL DESIGNED FOR ROTATING-DISK STUDIES IN BIOELECTROCHEMISTRY
    BARTLETT, PN
    WHITAKER, RG
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (24) : 2803 - 2805
  • [4] A SIMPLE INVITRO TECHNIQUE TO MEASURE THE RELEASE OF ENDOGENOUS DOPAMINE AND DIHYDROXYPHENYLACETIC ACID FROM STRIATAL TISSUE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    BECKER, JB
    CASTANEDA, E
    ROBINSON, TE
    BEER, ME
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1984, 11 (01) : 19 - 28
  • [5] Human norepinephrine transporter kinetics using rotating disk electrode voltammetry
    Burnette, WB
    Bailey, MD
    Kukoyi, S
    Blakely, RD
    Trowbridge, CG
    Justice, JB
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (17) : 2932 - 2938
  • [6] COMPARISON OF RELEASE OF ENDOGENOUS DOPAMINE AND GAMMA-AMINOBUTYRIC ACID FROM RAT CAUDATE SYNAPTOSOMES
    CAUDILL, WL
    BIGELOW, JC
    WIGHTMAN, RM
    [J]. NEUROCHEMICAL RESEARCH, 1985, 10 (03) : 319 - 331
  • [7] EFFECTS OF CELL DESIGN ON ELECTROCHEMICAL MEASUREMENTS IN SUBMICROLITER VOLUMES
    CLARK, ME
    INGRAM, JL
    BLAKELY, EE
    BOWYER, WJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 385 (02): : 157 - 162
  • [8] DANECK K, 1998, IN PRESS METHODS ENZ
  • [9] DRAPEAU P, 1983, J NEUROSCI, V3, P703
  • [10] DUGGLEBY RG, 1995, METHOD ENZYMOL, V249, P61