Aerosol particle number size distributions (3-400 nm) were measured for three weeks both indoors and outdoors in a family house with natural ventilation in Espoo, Finland. We investigated the indoor-to-outdoor relationship of aerosol particles and analyzed the effects of indoor activities on the particle number size distributions. We also estimated the decay rate of indoor aerosol particle number concentrations. As expected, in the absence of indoor sources of aerosol particles the indoor particles originated from outdoors and the number concentrations followed similar patterns as those outdoors. The. maximum penetration was found for particles between 100 and 4,00 nm in diameter. The mean value of the I/O values Was 0.36 for ultrafine particles (UFP diameter < 100 nm) and 0.60 for particles larger than 100 nm in diameter. Because of the penetration and deposition processes of aerosol particles, the modal structure of indoor particle number size distributions had larger geometric mean diameters and significantly lower number concentrations of UFP than those outdoors. The natural ventilation did not provide a stable and controlled indoor-to-outdoor relationship of aerosol particles and it caused variable I/O values and time-lags (10-45 min). In the presence of indoor activities, the indoor particle number concentrations cannot be directly estimated from the outdoor number concentrations only. The loss rate of UFP in the indoor air ranged from 1 h(-1) for 10nm particles to 0.1 h(-1) for 100nm particles in diameter. The quantitative and qualitative results presented in the current study are building and condition specific. However, the results provide a better understanding of the particle number size distribution characterizations indoors, especially during different indoor activities. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3697 / 3709
页数:13
相关论文
共 45 条
[1]   Physical characterization of aerosol particles during nucleation events [J].
Aalto, P ;
Hämeri, K ;
Becker, E ;
Weber, R ;
Salm, J ;
Mäkelä, JM ;
Hoell, C ;
O'Dowd, CD ;
Karlsson, H ;
Hansson, HC ;
Väkevä, M ;
Koponen, IK ;
Buzorius, G ;
Kulmala, M .
TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2001, 53 (04) :344-358
[2]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[3]  
[Anonymous], IND VENTILATION DESI
[4]  
Asmi AJ, 2004, SCAND J WORK ENV HEA, V30, P63
[5]   Design of a DMA-based size spectrometer for a large particle size range and stable operation [J].
Birmili, W ;
Stratmann, F ;
Wiedensohler, A .
JOURNAL OF AEROSOL SCIENCE, 1999, 30 (04) :549-553
[6]   Penetration coefficient and deposition rate as a function of particle size in non-smoking naturally ventilated residences [J].
Chao, CYH ;
Wan, MP ;
Cheng, ECK .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (30) :4233-4241
[7]   FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS [J].
HANLEY, JT ;
ENSOR, DS ;
SMITH, DD ;
SPARKS, LE .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03) :169-178
[8]  
Hussein T, 2004, SCAND J WORK ENV HEA, V30, P54
[9]  
HUSSEIN T, 2005, IN PRESS ATMOSPHERIC
[10]   Control strategies for sub-micrometer particles indoors: model study of air filtration and ventilation [J].
Jamriska, M ;
Morawska, L ;
Ensor, DS .
INDOOR AIR, 2003, 13 (02) :96-105