The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic volume conductor model

被引:23
作者
Deurloo, KEI [1 ]
Holsheimer, J [1 ]
Bergveld, P [1 ]
机构
[1] Univ Twente, Inst Biomed Technol, Dept Elect Engn, NL-7500 AE Enschede, Netherlands
关键词
D O I
10.1007/s004220100253
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The influence of subthreshold depolarizing prepulses on the threshold current-to-distance and the threshold current-to-diameter relationship of myelinated nerve fibers has been investigated. A nerve fiber model was used in combination with both a simple, homogeneous volume conductor model with a point source and a realistic, inhomogeneous volume conductor model of a monofascicular nerve trunk surrounded by a cuff electrode. The models predict that a subthreshold depolarizing prepulse will desensitize Ranvier nodes of fibers in the vicinity of the cathode and thus cause an increase in the threshold current of a subsequent pulse to activate these fibers. If the increase in threshold current of the excited node is large enough, the excitation will be accompanied by a strong hyperpolarization of adjacent nodes, preventing the propagation of action potentials in these fibers. As fibers close to the electrode are more desensitized by prepulses than more distant ones, it is possible to stimulate distant fibers without stimulating such fibers close to the electrode. Moreover, as larger fibers are more desensitized than smaller ones, smaller fibers have lower threshold currents than larger fibers up to a certain distance from the electrode. The realistic model has provided an additional condition for the application of this method to invert nerve fiber recruitment, i.e., real or virtual anodes should be close to the cathode. When using a cuff electrode for this purpose, in the case of monopolar stimulation the cuff length (determining the position of the virtual anodes) should not exceed twice the internodal length of the fibers to be blocked. Similarly, the distance between cathode and anodes should not exceed the internodal length of these fibers when stimulation is to be applied tripolarly.
引用
收藏
页码:281 / 291
页数:11
相关论文
共 19 条
[1]  
Boyd I.A., 1968, COMPOSITION PERIPHER
[2]  
CHIU SY, 1979, J PHYSIOL-LONDON, V292, P149, DOI 10.1113/jphysiol.1979.sp012843
[3]   Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity [J].
Deurloo, KEI ;
Holsheimer, J ;
Boom, HBK .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (01) :66-74
[4]   SELECTIVE ACTIVATION OF SMALL MOTOR AXONS BY QUASITRAPEZOIDAL CURRENT PULSES [J].
FANG, ZP ;
MORTIMER, JT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (02) :168-174
[5]   Modeling study of activation and propagation delays during stimulation of peripheral nerve fibers with a tripolar cuff electrode [J].
Goodall, Eleanor V. ;
Kosterman, L.Martin ;
Holsheimer, Jan ;
Struijk, Johannes J. .
IEEE Transactions on Rehabilitation Engineering, 1995, 3 (03) :272-282
[6]   Position-selective activation of peripheral nerve fibers with a cuff electrode [J].
Goodall, EV ;
deBreij, JF ;
Holsheimer, J .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (08) :851-856
[7]   Quantification of recruitment properties of multiple contact cuff electrodes [J].
Grill Jr., W.M. ;
Mortimer, J.T. .
IEEE Transactions on Rehabilitation Engineering, 1996, 4 (02) :49-62
[8]   Inversion of the current-distance relationship by transient depolarization [J].
Grill, WM ;
Mortimer, JT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (01) :1-9
[9]   Modeling the effects of electric fields on nerve fibers: Influence of tissue electrical properties [J].
Grill, WM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (08) :918-928
[10]   STIMULUS WAVE-FORMS FOR SELECTIVE NEURAL STIMULATION [J].
GRILL, WM ;
MORTIMER, JT .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (04) :375-385