Role of electrons in laser desorption/ionization mass spectrometry

被引:80
作者
Frankevich, VE [1 ]
Zhang, J [1 ]
Friess, SD [1 ]
Dashtiev, M [1 ]
Zenobi, R [1 ]
机构
[1] Swiss Fed Inst Technol, ETH Honggerberg, Swiss Fed Inst Technol, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
关键词
D O I
10.1021/ac034436j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nonmetallic sample support for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry enhances the positive ion yield by 2 orders of magnitude and generally affects the charge balance in the desorption plume. We interpret the effects of the target material and of the sample preparation on MALDI mass spectra as a result of photoelectrons emitted upon laser irradiation of a metal target covered by a thin sample layer. These electrons are shown to play an important role in MALDI and laser desorption/ionization because they decrease the yield of positive ions, reduce ions with higher oxidation states, and affect the ion velocity distribution as well as the mass resolution. Understanding the role of these photoelectrons helps to clarify previously obscure aspects of the ion formation mechanism in MALDI.
引用
收藏
页码:6063 / 6067
页数:5
相关论文
共 40 条
[1]   Electron capture negative ion mass spectra of some typical matrix-assisted laser desorption/ionization matrices [J].
Asfandiarov, NL ;
Pshenichnyuk, SA ;
Fokin, AI ;
Lukin, VG ;
Fal'ko, VS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) :1760-1765
[2]  
Baykut G, 2000, RAPID COMMUN MASS SP, V14, P1238, DOI 10.1002/1097-0231(20000730)14:14<1238::AID-RCM17>3.0.CO
[3]  
2-H
[4]   POLYETHYLENE MEMBRANE AS A SAMPLE SUPPORT FOR DIRECT MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRIC ANALYSIS OF HIGH-MASS PROTEINS [J].
BLACKLEDGE, JA ;
ALEXANDER, AJ .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :843-848
[5]  
CHAPMAN JR, 2000, MASS SPECROMETRY PRO
[6]   Electron interactions with SF6 [J].
Christophorou, LG ;
Olthoff, JK .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 2000, 29 (03) :267-330
[7]   A 4.7 Tesla internal MALDI-FTICR instrument for high mass studies: Performance and methods [J].
Easterling, ML ;
Pitsenberger, CC ;
Kulkarni, SS ;
Taylor, PK ;
Amster, IJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 157 :97-113
[8]   Corona discharge in charge reduction electrospray mass spectrometry [J].
Ebeling, DD ;
Westphall, MS ;
Scalf, M ;
Smith, LM .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5158-5161
[9]   The origin of electrons in MALDI and their use for sympathetic cooling of negative ions in FTICR [J].
Frankevich, V ;
Knochenmuss, R ;
Zenobi, R .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 220 (01) :11-19
[10]   Flexible open-cell design for internal-source matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Frankevich, V ;
Zenobi, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) :979-985